10-806-01
3.2. Connecting a door opener
Internal resistance of
the door opener
> 6 Ω
< 6 Ω
3.3. Connecting a lighting circuit
Connect the lighting circuit to terminals 10 and 11 of the power supply. This is the
potential-free contact (max. 24 V and 1 A) of the power supply.
3.4. Testing the connection
Action
Switch on the power supply.
Briefly press the speech key on the
internal unit to initiate a conversation
with the visitor.
Press one of the unprogrammed push
buttons on the external unit or a specific
push button on the internal unit.
EN
Action
1. Connect the door opener to terminals 13 and 14
(8-12 Vac) of the power supply.
1. Add a transformer (10-819) to the electrical cabinet.
2. Connect the door opener to terminals 12 and 0 of
the power supply (see figure below).
32
33
P
b
Industriepark West 40
10-806-01
BE-9100 Sint-Niklaas
www.niko.eu
24V - 2A
24V - 2A
1
3
10
11
12
13
230 V - 50-60 Hz - 0,1 A
8-24V
t
= 40 °C
a
t
max.
34
16 VA
8 s
a
12V
1,34A
8V
2A
t
max.
5 min
SEC
RUN
12 VAC
PRI
14
PROG
230-240 V
50- 60 Hz
RUN
PROG
ta 45/E
IP20
EN 61558-2-8
Result
The LED on the video power supply lights
up. The name plate of the external video
unit is illuminated.
The image of the visitor appears on the internal
unit. The communication is interrupted by
pressing briefly on the speech key again,
or it will be automatically interrupted after
one minute.
You will hear a beep. The lighting relay
from the power supply is switched on.
10-819
PTC
28