Alarm codes and resetting

Alarm
AL
Minimum temperature alarm. Check ambient temperature from parameter A1.
AH
Maximum temperature alarm. Check ambient temperature from parameter A4.
COH
Condenser overheating alarm. Check condenser temperature (see parameter C6).
CSd
Compressor blocked alarm.
EN
Defrost ended for maximum
dFd
If the appliance detects a malfunction, an alarm code flashes on the display.
Normal function is restored automatically when the cause of the alarm is removed.
The alarms that require manual intervention are:
– CSd (compressor blocked alarm): turn the device off or disconnect the mains power
– dFd (defrost finished for maximum time alarm): press any key
a
WARNING
If an alarm persists, contact the dealer who sold the appliance.
3.5

Interior equipment

refrigerated display cabinets are supplied with their
MIAMI
interior equipment already installed. If certain compartments
have been specified with a "tube" display solution, the tubes
(1) must be fitted as shown in the figure.
An LED lighting system illuminates the various sections of
the refrigerated cabinet to ensure an optimal view of the pro-
ducts on display.
In the event of a malfunction or failure of the lighting system,
contact the dealer who sold the appliance.
38
Meaning
Solutions
Check condenser temperature (see parameter C7).
Turn the appliance off and on again (section "Turning cabi-
nets lights on/off"). If condenser temperature remains above
that set in parameter C7, switch off electric power (section
"Connecting to the electricity supply") and clean the con-
denser.
Press any key to restore the normal display.
time alarm.
3.5.1

Temperature distribution

Temperature distribution inside the refrigerated cabinet can
be changed to suit its use. There are two functioning modes:
– ventilated (*)
– static.
STATIC
+12°C
+9°C
1
Fig. 13
+6°C
(*) Not available for MIAMI MINI models.
In ventilated mode, temperature is distributed uniformly
throughout the cabinet. In static mode, natural temperature
stratification occurs: the bottom section of the cabinet is col-
dest, the top warmest.
Consequences
The device will function
normally.
The device will function
normally.
The device will function
normally.
The compressor will switch off.
The device will function
normally.
VENTILATED