Record the maintenance details in table A in
the appendix at the back of this book.
7
SPARE PARTS
For operation we advise you to have spare
parts in store. See table B in the appendix.
8
TECHNICAL INFORMATION
•
For the technical specifications, see table
B in the appendix at the back of this
book.
9
INSTALLATION OF ACCESSORIES
9.1
Flue with rain cover (fig. 4)
The heater is provided with a flue connection.
1. Fit a flue (B) to the flue connection (C).
Caution
The flue must point upwards. Never
place the flue pipe horizontal. An
angle of 45° is acceptable; minimum
length flue 4 ft.
2. Fit a raincover (A) to the end of the flue.
9.2
Outlet hose
An outlet hose can be fitted to the outlet of
the heater, in order to blow heated air to a
remote space away from the heater.
Caution
Check the temperature resistance of
the used hose.
/i
Single
ITA 30-
outlet
US
ITAS 30-
US
Max.
-
length
ITA/ITAS-US
ITA 45-
ITA 75-
US
US
ITAS 45-
ITAS 75-
US
US
L = 60 ft:
L = 40 ft:
∅16 in
∅16 in
40.020.945 - rev. 04 - 2011
/i
Two
ITA 30-
way
US
outlet
ITAS 30-
US
Max.
-
length
Please contact the dealer for information
about maximum lengths of outlet hoses,
bends, distribution pipes and hose clamps.
9.3
Room thermostat
See the instructions of the room thermostat.
10
STANDARDS AND GUIDELINES
For the standards and guidelines, go to
www.thermobile.nl.