Warning
Make sure that the convector
heater has cooled off sufficiently
and that the plug has been
removed from the socket before
carrying out any repair or
maintenance work.
1.6
Additional safety
Warning
Connect the heater only to a
1-phase 120 V / 60 Hz power
supply.
Replace fuses only with identical
spares.
The heater must be grounded.
Warning
Use only No.1 fuel, No.2 fuel or
Diesel.
Do not use gasoline or crankcase
oils.
Place the separate fuel tank at
least 7 ft from the heater.
Do not fill the tank while the
heater operates.
When the static pressure is not
within the limitation of the heater,
this can cause damage to the fan
motor or heat exchanger.
The maximum static pressure in the duct
system is 10.44 lb/ft
The maximum air temperature of the
ducts is 220 °F.