SOEL-
Instructions of use
Control panel
The SOEL-RTD-Q50-PP-S-7 has various modes and is configured using the S and T buttons.
Button
Set button:
Toggle button:
The selected settings and signal condition are indicated by LEDs.
BA
ZA
Q
Q
1
2
H
OK
T
Z
S
T
Illustr. 9
15400272
The table of functions on page 28 explains the further significance of the LEDs: Q
General use
The following four steps are used to configure the SOEL-RTD-Q50-PP-S-7 sensor:
1. Activate setting mode
Press the S and T buttons simultaneously for 3 seconds
After this period, the power supply indicator BA flashes
set SOEL-RTD-Q50-PP-S-7, see Illustr. 9. The LEDs show the status of function no. 1 (page 28)
When all the LEDs start immediately flashing
Unlock SOEL-RTD-Q50-PP-S-7, see paragraph "Unlocking keys" on page 34
2. Select functions (see page 28)
Press the T button to select the next function in the function table.
The function number is indicated by a clear LED pattern and the function status is indicated by the status indicator ZA (LED
on = active, LED off = not active).
The sensor only switches to the next function when the T button is released.
26
Change / confirm a setting or set a switching point
Select a function
LED
Colour
BA
Green
ZA
Red
Q
Yellow
1
Q
Yellow
2
H
Green
OK
Green
T
Green
Z
Green
Use/Description
Power supply indicator
On: ready (run mode)
Flashing: setting mode is active
Status indicator
Function activated/not activated, or confirmation signal
Q
input/output
1
Q
input/output
2
Q
trigger input or Q
enable input function active
1
1
Good target (object detected and in measuring range)
Pulse stretching function is active
Q
automatic centre or Q
1
automatic zero function is active
1
, Q
, H, OK, T and Z
1
2
Festo SOEL-...0608b English