Mounting the exhaust accessories.
The air conditioning system cools the air in the room where unit is placed. The absorbed heat
of the conditioned air, should be removed to outside the room where the unit is placed.
During cooling of hot air condenswater will be created. Much of the condensation will be
transported with the warm air to outside. At high humidity not all the condense will be
transported with the warm air to the outside, the water tank must regularly be emptied.
In the chapter "Condensate Drain" is this defined step by step.
There are several ways to transport warm air out of the room:
•
Attach the hose (No. 10) in the warm air outlet (No. 8) of the device. Hang the hose out
the window or a door. The cooling capacity will not be optimal because of warm outside
air will flow into the to cool area.
•
Drill a hole of 135 mm. diameter in the outer wall and enter the tubing through the hole.
The cool capacity is now optimal.
•
Screw the adapter (No. 13) at the end of the hose (No. 10). Place the window spacer in
the open section of the window. Insert the adapter into the socket for the adapter (No. 12).
The cool capacity is optimal. Provide a maximum distance of 36 cm. the device to the
windows or exterior wall.
Make sure that the hose (No. 10) is not
kinked or that the air flow is obstructed.
Never extend the hose (No. 10).
13