Télécharger Imprimer la page

Beninca THINK Serie Mode D'emploi page 14

Masquer les pouces Voir aussi pour THINK Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
The activation time of the courtesy light is adjusted. The contact closes with the be-
TLS
ginning of the opening operation. The time counting starts only with gate completely
closed.
This is operating only with logic SMOT:ON. The motor protection switch triggering is
adjusted. The value is expressed in Amperes.
SaFM
1:
triggering of protection switch at 1 Ampere of consumption
14:
protection disabled.
An incorrect setting of these parameters may cause danger. Please comply with regulations in force!
MENU
The automatic closure is enabled or disabled.
TCA
Off: disabled automatic closure.
On: enabled automatic closure.
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
IbL
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the
transmitter has no effect in the opening phase.
The rapid closure is enabled or disabled.
On: enabled rapid closure. With open gate or gate in the opening phase, the activation
SCL
of the photocell causes the automatic closure of the gate 3 sec after its activation. This
function is enabled only with TCA:ON
Off: rapid closure disabled.
The operating mode The operating mode of the "P.P." (Step-by Step) button and of the
transmitter is selected.
PP
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation : OPEN > CLOSE > OPEN >
Forewarning flashing light enabled or disabled.
Off: disabled forewarning flashing light.
PRE
On: enabled forewarning flashing light. The flashing light is activated 3 sec before the
motor starts.
The OPEN input mode is selected.
Off: OPEN input, with OPEN function.
CLOC
On: OPEN input, with CLOCK function.
To be used for connection to timer for timed opening/closing. (CLOSED contact: open
gate. OPEN contact: normal operation).
The Service Man function is enabled or disabled.
Off: Automatic operation.
htr
On: Service Man operation.
The OPEN/CLOSE push-buttons should be kept pressed for the entire operating time.
The lock function is enabled or disabled.
Off: Lock function disabled.
On: Lock function enabled. After the triggering of the closure limit switches, the control
BLC
unit delays the stop by approx. 0.5sec in order to allow a better resting of the gate leaf
onto the stoppers. DAS input is activated in the closing phase only.
Note: In case of sliding gates, leave to OFF.
Photocell 1 input in the opening phase is enabled or disabled.
Pho1
On: Photocell 1 is activated in the closing phase only.
Off: Photocell 1 is activated in both opening and closing phases.
Photocell 2 input in the opening phase is enabled or disabled.
Pho2
On: Photocell 2 is activated in the closing phase only.
Off: Photocell 2 is activated in both opening and closing phases.
Photocell 3 input in the opening phase is enabled or disabled.
Pho3
On: Photocell 3 is activated in the closing phase only.
Off: Photocell 3 is activated in both opening and closing phases.
Photocell 4 input in the opening phase is enabled or disabled.
Pho4
On: Photocell 4 is activated in the closing phase only.
Off: Photocell 4 is activated in both opening and closing phases.
The operating mode of output SCA/TESTPHOT is selected.
On: Photocell power supply in Test mode as per diagram at page 4. Before each
TSTP
operation all PHOT inputs are checked. If the result is negative, the operation will not
take place.
Off: Output preset as open gate warning LED.
14
* WARNING:
LOGIC (LOGI)
FUNCTION
1-240-(1s)
1-14-(6A)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)

Publicité

loading

Ce manuel est également adapté pour:

Think-iThink-pThink