The check function of single failure is enabled or disabled.
Faut
Off: Single failure check is disabled.
On: Single failure check enabled in compliance with the Machinery Directive 98/37/CE.
The anti-crash amperometric sensor is disabled or enabled. Its sensitivity is adjusted
by parameters SNSO and SNSC.
AMP
On: Amperometric sensor activated.
Off: Amperometric sensor deactivated.
Lack of phase check in case of three-phase power supply is enabled or disabled.
2pha
On: Check activated.
Off: Check deactivated.
The movement reversion in the event of triggering of the amperometric sensor or the
DAS input is activated or deactivared.
On: Reversion activated. The activation of the edge or the sensor causes a movement
inva
reversion (opening) for approx. 3 sec.
Off: Movement reversion not activated. The activation of the edge or the sensor causes
the immediate stopping of the gate movement.
The motor protection switch is enabled or disabled. Its sensitivity is adjusted by SAFM
parameter.
Smot
On: amperometric sensor activated.
Off: amperometric sensor deactivated.
The rapid movement reversion is enabled or disabled after the activation of the photo-
cell in the closing phase.
ON: Rapid reversion activated. The movement reversion time, in the event of activation
doSp
of the photocell, is reduced to approx. 1 sec.
To be used only on light-weight and fast doors.
OFF: Rapid reversion deactivated. The movement reversion time, in the event of activa-
tion of the photocell, is approx. 3 sec.
Auxiliary capacitor
disg
On: 230Vac motor - single-phase and Auxiliary capacitor (terminal 7/8)
Off: 400Vac motor - Three-phase .
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, the last 4
digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button<PG> is pressed once more,
the control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the receiver.
NUMBER OF CYCLES (Nman)
RESET (RES)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
15