TECHNICAL DATA
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Terminal No. Function
1-2-3
Motor
4-5
Flashing light
5-6
AUX
Auxiliary
7-8
capacitor
9-10
Courtesy light
11-12
24Vac
13-14
SCA/PhotoTest
15
COM
16
SWO
17
SWC
18
PHOT 1
19
PHOT 2
20
PHOT 3
21
PHOT 4
22
STOP
23
OPEN
24
CLOSE
25
PED
26
Step-by-step
27
COM
12
230 Vac 50/60 Hz
1 motor 230Vac single-phase / 400Vac three-phase
230Vac single-phase: 800 W
400Vac three-phase: 2200 W
24Vdc 500mA max.
IP54
-20°C / +50°C
Removable connector for radio receiver
THINK Control Unit
INPUT/OUTPUT FUNCTIONS
THINK Control Unit
Description
Connection, 230Vac motor - single-phase:
1-Movement+capacitor/2-Common/3-Movement+capacitor
Connection, 400Vac motor - three-phase:
1-U/2-V/3-W
Check that the voltage selection jumper on terminals 36-37-38 is correctly positioned.
Connection of flashing light, 230Vac 40W max.
Connect a negative electric brake to this output.
WARNING: Output, 230Vac 0,5A max.
Output N.O. (10A max) for pickup auxiliary capacitor. See wire diagram.
WARNING: 230Vac motor - single-phase only.
DISG Logic must be set ON
Free N.O. contact (2A 150W) to control the Courtesy light which is timed according to the
TLS parameter.
Output, accessory power supply 24Vac/0,5A max
Output, 24Vac/0,5A max. This can be preset as open gate indicator light or as checked
devices power supply (PhotoTest) through the TSTP logic.
In the event of presetting as PhotoTest, please refer to the diagram "Connection of checked
safety devices"
Common for limit switches and photocells
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input, Photocell 1 (N.C. contact). It can be disabled in the opening phase, see PHO1 logic.
Input, Photocell 2 (N.C. contact). It can be disabled in the opening phase, see PHO2 logic.
Input, Photocell 3 (N.C. contact). It can be disabled in the opening phase, see PHO3 logic.
Input, Photocell 4 (N.C. contact). It can be disabled in the opening phase, see PHO4 logic.
Input, STOP push-button (N.C. contact)
Input, OPEN push-button (N.O. contact).
Input, CLOSE push-button (N.O. contact)
Input, pedestrian push-button (N.O. contact)
Input, step-by-step (N.O. contact)
Common for all other control inputs.