Each input is matched to one segment of the display; in the event of activation, it switches on according to the following diagram.
The Normally Closed (N.C.) inputs are represented by vertical segments. The Normally Open (N.O.) inputs are represented by
horizontal segments.
The control unit checks the correct operation of the safety devices.
In the event of faults the following messages can be displayed:
ERR1
Error, check photocells. Check connections and the correct operation of photocells.
ERR2
Activation of the anti-crash amperometric sensor. Check the presence of any obstacles.
ERR3
Check of single failure has negative result. Contact the technical assistance.
ERR4
Triggering of the motor protection switch. Check the value of the parameter SAFM and check the motor consumption.
ERR5
Lack of one of the three phases. Check the correct connection of power supply of the three-phase mains.
F1
Protection fuse, accessories
F2
Protection fuse, logic board
F3
Protection fuse, flashing light and electric brake.s
F4
Primary protection fuse of the transformer.
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal
and the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a
specialised company.
Diagnostics
PHOT3
SWO
SWC
PHOT4
P.P.
PED
OPEN
PHOT1
STOP
PHOT2
DAS
Error messages
Fuses
Waste Disposal
CLOSE
17