Jotul I 150 FL Manuel D'installation Et Données Techniques page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Table of contents
Installation manual with technical data
1.0
Relationship to the authorities .................. 15
2.0
Technical data .............................................. 15
3.0
Installation .................................................16
4.0
Service .......................................................... 18
5.0
Optional Equipment ................................... 18
Figures .................................................................. 40
Table of contents
General use and maintenance manual
6.0
Safety precautions
7.0
Choice of fuel
8.0
Use
9.0
Maintenance
10.0
Operational problems - troubleshooting
On all our products there is a label
Product:
Jøtul
indicating the serial number and
Room heater fired by solid fuel
year. Write this number in the
Standard
:
Minimum distance to adjacent combustible materials:
place indicated in the installation
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
:
Flue gas temperature
:
instructions.
Nominal heat output
:
Efficiency
:
Operation range
:
Fuel type
:
Operational type
:
The appliance can be used in a shared flue.
Always quote this serial number when
Country
Classification
Certificate/
Approved by
contacting your retailer or Jøtul.
standard
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EN
EUR
Intermittent
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those which refer to national
and European standards, must be observed when installing the
product.
Both an installation manual with technical data and a manual
on general use and maintenance are enclosed with the product.
The installation can only be used after it has been inspected by
a qualified inspector.
A name plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max.:
Operating range:
Flue outlet:
Flue pipe dimension:
Weight:
Options extras:
Dimensions, distances:
Technical data according to EN 13229:
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught: 12 Pa
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational type:
Intermittent combustion in this context means normal use of the
fireplace, i.e. fuel is added as soon as the fuel has burnt down to
a suitable amount of embers.
engliSh
Cast iron
Black or grey varnish
Wood
40 cm
2,6 - 7,8 kW
Top
Ø150 mm, 177 cm
cross
2
section
99 kg
Ash solution
See fig. 1
6,0 kW
5,8 g/s
75%@6,8kW
0,16%
342
C
o
Intermittent
15