Télécharger Imprimer la page

Axis Q1615-E Mk II Mode D'emploi page 24

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
AXIS Q1615-E Mk II Network Camera
• The view in front of the camera should not be changed during focus adjustment (steps
5 and 6). If the camera is moved, or if a finger or other object is placed in front of the
lens, steps 3–7 will have to be repeated.
• If movements in front of the camera cannot be avoided, the Focus Assistant should not
be used.
• If the camera is mounted so that the function button cannot be accessed, you can still
use the Focus Assistant. Follow the instructions below but mount the camera after step
4, pressing the function button instead and skip step 7.
To focus your network camera using the Focus Assistant, follow steps 1–4 under Adjust zoom and
focus for optional lenses on page 23 before you start with the steps below.
1. Mount or place the camera so that it cannot be moved.
2. Loosen the zoom puller by turning it counter-clockwise. Move the puller to set the
zoom level. Re-tighten the zoom puller.
3. Set the camera to its extreme distant-focus position by loosening the lock screw for the
focus ring and turning the focus ring fully counter-clockwise.
4. Press and quickly release the function button. When the Status LED flashes green, the
Focus Assistant is enabled.
If the Status LED flashes either red or amber before you are able to adjust the lens, skip
to step 7 to exit the Focus Assistant and repeat steps 3–7. See the notes above. See
Status LED behavior for focus assistant on page 13.
5. Gently turn the focus ring clockwise until it stops.
6. Turn the focus ring slowly counter-clockwise until the status indicator flashes green
or amber (not red).
7. To exit the Focus Assistant, press the function button again. The Focus Assistant is
switched off automatically after 15 minutes.
8. Retighten the lock screw for the focus ring.
9. If the image focus has slightly changed while tightening the zoom and focus pullers,
click Fine-tune.
10. If you want to slightly move focus position, move the Focus position slider.
Reset to factory default settings
Important
Reset to factory default should be used with caution. A reset to factory default resets all
settings, including the IP address, to the factory default values.
To reset the product to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the control button while reconnecting power. See Product overview on
page 10.