The internal microphone is used by default; the external microphone is used when connected. It is
possible to disable the internal microphone by connecting a plug to the mic input.
RS485/RS422 connector
Two 2-pin terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment
such as pan-tilt devices.
The serial port can be configured to support:
•
Two-wire RS485 half duplex
•
Four-wire RS485 full duplex
•
Two-wire RS422 simplex
•
Four-wire RS422 full duplex point to point communication
Function
RS485B alt
RS485/422 RX(B)
RS485A alt
RS485/422 RX(A)
RS485/RS422 TX(B)
RS485/RS422 TX(A)
Important
The maximum cable length is 30 m (98 ft).
Install the hardware
Do the following to install the wall bracket:
Note
• The weight of the camera is 3525 g (7.7 lb). Check that the material is strong enough to
support this weight.
AXIS Q1615-E Mk II Network Camera
Pin
Notes
1
RX pair for all modes (combined RX/TX for 2-wire RS485)
2
3
TX pair for RS422 and 4-wire RS485
4
19
EN