Weitere Sprachversionen finden Sie online unter www.kern-sohn.com/manuals Další jazykové verze najdete na webu pod adresou www.kern-sohn.com/manuals Más versiones de idiomas se encuentran online bajo www.kern-sohn.com/manuals Vous trouverez d’autres versions de langue online sous www.kern-sohn.com/manuals Muut kieliversiot löytyvät osoitteesta www.kern-sohn.com/manuals Further language versions you will find online under www.kern-sohn.com/manuals Trovate altre versioni di lingue online in www.kern-sohn.com/manuals Bijkomende taalversies vindt u online op www.kern-sohn.com/manuals Encontram-se online mais versões de línguas em www.kern-sohn.com/manuals...
+ 15° C ..+ 30° C Luftfeuchtigkeit max. 80 % (nicht kondensierend) Unterflurwägeeinrichtung Haken Gehäuse (B x T x H) mm 210 x 335 x 88 Wägeplatte (Edelstahl) mm 128 x 128 195 x 195 Gewicht kg (netto) 3,6 kg PLJ-GM-BA-d-1614...
2 Konformitätserklärung Die aktuelle EG/EU-Konformitätserklärung finden Sie online unter: www.kern-sohn.com/ce Bei geeichten Waagen (= konformitätsbewerteten Waagen) ist die Konformitätserklärung im Lieferumfang enthalten. PLJ-GM-BA-d-1614...
• Nichtbeachten unserer Vorgaben in der Betriebsanleitung • Verwendung außerhalb der beschriebenen Anwendungen • Veränderung oder Öffnen des Gerätes • Mechanische Beschädigung und Beschädigung durch Medien, Flüssigkeiten, natürlichem Verschleiß und Abnützung • Nicht sachgemäße Aufstellung oder elektrische Installation • Überlastung des Messwerkes PLJ-GM-BA-d-1614...
4.2 Ausbildung des Personals Das Gerät darf nur von geschulten Mitarbeitern bedient und gepflegt werden. 5 Transport und Lagerung 5.1 Kontrolle bei Übernahme Überprüfen Sie bitte die Verpackung sofort beim Eingang sowie das Gerät beim Auspacken auf eventuell sichtbare äußere Beschädigungen. PLJ-GM-BA-d-1614...
5.2 Verpackung / Rücktransport Alle Teile der Originalverpackung für einen eventuell notwendi- gen Rücktransport aufbewahren. Für den Rücktransport ist nur die Originalverpackung zu verwen- den. Vor dem Versand alle angeschlossenen Kabel und lo- sen/beweglichen Teile trennen. PLJ-GM-BA-d-1614...
Page 10
Alle Teile z.B. Glaswindschutz, Wägeplatte, Netzteil etc. gegen Verrutschen und Beschädigung sichern. Netzadapter Wägeplatte (128 x 128 mm) Träger Wägeplatte Wägeplatte (195 x 195 mm) PLJ-GM-BA-d-1614...
Funkgeräte), bei statischen Aufladungen sowie bei instabiler Stromversorgung sind große Anzeigeabweichungen (falsche Wägeergebnisse) möglich. Der Standort muss dann gewechselt oder die Störquelle beseitigt werden. 6.2 Auspacken Die Waage vorsichtig aus der Verpackung nehmen, Plastikhülle entfernen und die Waage am vorgesehenen Arbeitsplatz aufstellen. PLJ-GM-BA-d-1614...
6.4 Anschluss von Peripheriegeräten Vor Anschluss oder Trennen von Zusatzgeräten (Drucker, PC) an die Datenschnitt- stelle muss die Waage unbedingt vom Netz getrennt werden. Verwenden Sie zu Ihrer Waage ausschließlich Zubehör und Peripheriegeräte von KERN, diese sind optimal auf Ihre Waage abgestimmt. PLJ-GM-BA-d-1614...
Waage nicht bereits im Werk auf den Aufstellort justiert wurde). Dieser Justier- vorgang muss bei der ersten Inbetriebnahme, nach jedem Standortwechsel sowie bei Schwankungen der Umgebungstemperatur durchgeführt werden. Um genaue Mess- werte zu erhalten, empfiehlt es sich zudem, die Waage auch im Wägebetrieb perio- disch zu justieren. PLJ-GM-BA-d-1614...
6.6.3 Ablauf der temperaturgesteuerten Justierung: Bei einer Temperaturänderung von 3 °C kündigt die Waa- ge mit der Anzeige „CALib“ die interne Justierung an Die Waage startet den Justiervorgang und zeigt „CAL-t“ Ist der Justiervorgang abgeschlossen, kehrt die Waage automatisch in den Wägemodus zurück. PLJ-GM-BA-d-1614...
Während des Justiervorgangs wird „CAL-H“ angezeigt Ist der Justiervorgang abgeschlossen, kehrt die Waage automatisch in den Wägemodus zurück. Mit der -Taste kann der Justiervorgang jederzeit abge- brochen werden. wird kurz angezeigt. Danach wechselt die Waage automatisch in den Wägemodus. PLJ-GM-BA-d-1614...
Position der Siegelmarken Eichpflichtige Waagen müssen außer Betrieb gesetzt werden, wenn: Das Wägeergebnis der Waage außerhalb der Verkehrsfehlergrenze liegt. Waage deshalb in regelmäßigen Abständen mit bekanntem Prüfgewicht (ca. 1/3 der max. Last) belasten und mit Anzeigenwert vergleichen. Nacheichungstermin überschritten ist. PLJ-GM-BA-d-1614...
• Niemals Lasten über die angegebene Höchstlast (Max) hinaus anhängen (Bruchgefahr) Es ist stets darauf zu achten, dass sich unter der Last keine Lebewesen oder Ge- genstände befinden, die Schaden nehmen könnten. HINWEIS Nach Beendigung der Unterflurwägung muss die Öffnung am Waagenboden unbe- dingt wieder verschlossen werden (Staubschutz). PLJ-GM-BA-d-1614...
• Aktivierung eines geänderten Parameters • Eingabe bestätigen PRINT 8.2 Aufruf des Menüs / Rücksprung in den Wägemodus 8.2.1 Aufruf des Menüs Waage mit einschalten. PRINT gleichzeitig drücken. mehrmals drücken um im Menü von P1.rEAD bis P6.CAL zu gelangen. PLJ-GM-BA-d-1614...
Selbsttest durch. Sobald die Gewichtsanzeige „0.00" anzeigt, ist die 0.00 g Waage wägebereit Wägegut auflegen, der Gewichtswert wird ange- 19.68 g zeigt. Warten bis Stabilitätsanzeige erscheint Ablesen des Wägewertes. Zum Ausschalten der Waage die drücken PLJ-GM-BA-d-1614...
P3.Unit erscheint TARE P3.1.StUn drücken TARE erneut drücken drücken, um Auswahl zu ändern� PRINT P3.1.StUn Mit der wird die Einstellung übernommen. PRINT mehrmals drücken, bis Anzeige SAvE ? erscheint. Mit die vorgenomme- nen Änderungen abspeichern. PLJ-GM-BA-d-1614...
Anzeige ab. Der Tariervorgang kann beliebige Male wiederholt werden, beispielsweise beim Ein- wiegen von mehreren Komponenten zu einer Mischung (Zuwiegen). Die Grenze ist dann erreicht, wenn der gesamte Wägebereich ausgelastet ist. Nach Abnehmen des Taragefäßes erscheint das Gesamtgewicht als Minus-Anzeige. PLJ-GM-BA-d-1614...
TARE drücken die in Menü 4.2 bis 4.b freigegeben sind Funi Wägeeinheiten drücken Stückzählen drücken HiLo Toleranzwägung drücken Prozentanzeige durch PrcA drücken Wägung Prozentanzeige über Prcb drücken manuelle Vorgabe AtAr Autotarieren drücken PLJ-GM-BA-d-1614...
Page 27
Wenn im Menü 4.1.FFun der Parameter auf ALL gesetzt ist, kann mit auf die Funktionen zugegriffen werden, die im Menü P4 Func auf YES gesetzt sind. Wird im Menü 4.1.FFun hingegen einer der obigen Parameter ausgewählt z.B. PcS, so kann mit lediglich dieser eine Menüpunkt aufgerufen werden. PLJ-GM-BA-d-1614...
Die Aktivierung erfolgt wie bei der Stück- zählung beschrieben Diesen Vorgang für jede weitere verfügbare Betriebsart wiederholen. 4.2.Funi 4.3.PcS 4.4.HiLo 4.5 PrcA 4.6 Prcb 4.7 AtAr 4.8 toP PRINT mehrmals drücken, bis Anzeige SAvE ? erscheint. Mit die vorgenomme- nen Änderungen abspeichern. PLJ-GM-BA-d-1614...
TARE Auto drücken drücken, um Auswahl zu ändern� drücken, um Auswahl zu ändern PRINT 5.1.bl Mit wird die Einstellung übernommen. PRINT mehrmals drücken, bis Anzeige SAvE ? erscheint. Mit die vorgenomme- nen Änderungen abspeichern. PLJ-GM-BA-d-1614...
drücken 30 40 … 100 no drücken, um Auswahl zu ändern� PRINT 5.2.blbA Mit wird die Einstellung übernommen. PRINT mehrmals drücken, bis Anzeige SAvE ? erscheint. Mit die vorgenomme- nen Änderungen abspeichern. PLJ-GM-BA-d-1614...
Auswahl des Menüpunktes P5 othr TARE 5.1.bl drücken 5.3.bEEP mehrmals drücken bis folgende Anzeige er- scheint TARE drücken, um Auswahl zu ändern� drücken, um Auswahl zu ändern PRINT 5.3.bEEP Mit wird die Einstellung übernommen. PLJ-GM-BA-d-1614...
1 Sekunde später 2 Sekunden später� 0.00 g Nachdem der Ladezustand des Akkus angezeigt wurde kehrt die Waage in den Wägemodus zurück. Das Anzeigesymbol ( bat low ) wird aktiviert, wenn der Ladezustand des Akkus 18 % unterschreitet. PLJ-GM-BA-d-1614...
drücken OFF 1 2 3 4 drücken, um Auswahl zu ändern� PRINT 1.1.Fil Mit wird die Einstellung übernommen. PRINT mehrmals drücken, bis Anzeige SAvE ? erscheint. Mit die vorgenomme- nen Änderungen abspeichern. PLJ-GM-BA-d-1614...
Anzeige: Auswahl des Menüpunktes P1 rEAd TARE 1.1.Fil drücken 1.2.Auto drücken bis folgende Anzeige erscheint TARE drücken, um Auswahl zu ändern� drücken, um Auswahl zu ändern PRINT 1.2.Auto Mit wird die Einstellung übernommen. PLJ-GM-BA-d-1614...
1.3.tArA mehrmals drücken bis folgende Anzeige er- scheint TARE AtAr drücken, um Auswahl zu ändern� drücken, um Auswahl zu ändern� tArF drücken, um Auswahl zu ändern PRINT 1.3.tArA Mit wird die Einstellung übernommen. PLJ-GM-BA-d-1614...
Auswahl des Menüpunktes P1 rEAd TARE 1.1.Fil drücken 1.4.Fnnd mehrmals drücken bis folgende Anzeige er- scheint TARE drücken, um Auswahl zu ändern� drücken, um Auswahl zu ändern� PRINT 1.4.Fnnd Mit wird die Einstellung übernommen. PLJ-GM-BA-d-1614...
Referenzstückzahl auswählen (Beispiel) PRINT 0.0 g Mit bestätigen, „0.0“ erscheint und „PCS“ blinkt Ausgewählte Stückzahl an Teilen auflegen (Beispiel) PRINT Mit bestätigen (Beispiel) Anzahl der zu zählenden Teile auflegen, die Stückzahl wird an- gezeigt (Beispiel) PLJ-GM-BA-d-1614...
Page 39
Zurück in den Wägemodus durch Drücken von Wenn diese Funktion angewählt wird ( F-Taste gedrückt wird ), aber keine Referenz- teile auf der Wägeplatte vorhanden sind, erscheint kurz –Lo- im Display und die An- zeige der Waage kehrt in den Wägemodus zurück. PLJ-GM-BA-d-1614...
„00000,0“ erscheint, die erste Ziffer blinkt und „Min“ wird angezeigt 2,0 g TARE Mit das Minimalgewicht eingeben (Beispiel) PRINT Mit 00000,0 bestätigen, „00000.0“ erscheint, die erste Ziffer blinkt und „Max“ wird angezeigt 10.0 g TARE Mit das Maximalgewicht eingeben (Beispiel) PLJ-GM-BA-d-1614...
TARE drücken 4.1.FFun SAVE? so oft drücken, bis „SAVE?“ erscheint PRINT 0.0 g Mit bestätigen, „0.0“ erscheint drücken, „0.0“ erscheint und % wird blinkend ange- zeigt Referenzgewicht, das 100% entspricht, auflegen 35.8 g (Beispiel) PLJ-GM-BA-d-1614...
Ziffer blinkt, das %-Symbol wird blin- (Beispiel) kend angezeigt TARE 40.0 % Mit das Referenzgewicht eingeben PRINT 0.0 g Mit bestätigen, „0.0“ erscheint Prüfgewicht auflegen, das Gewicht wird in Prozent ange- 20.0 % zeigt PLJ-GM-BA-d-1614...
PRINT 0.0 g Mit bestätigen, „0.0“ erscheint drücken, Wägebehälter auflegen, kurzzeitig wird „--- ---„ angezeigt, danach wechselt die Waage automatisch zur „0.0“-Anzeige und „NET“ wird angezeigt Prüflinge in den Wägebehälter legen, der Nettogewichts- wert wird angezeigt PLJ-GM-BA-d-1614...
0.0 g drücken, „0.0“ wird angezeigt und das „Max“- Symbol wird angezeigt Gewicht auflegen 123.4 g (Beispiel) Weiteres Gewicht auflegen 235.8 g (Beispiel) Auch wenn alle Gewichtstücke entfernt werden, wird wei- 235.8 g terhin das Maximalgewicht angezeigt PLJ-GM-BA-d-1614...
Summiersymbol erscheint ein Dreieck Prüfling entfernen, „P“ und „0.0 g“ wird angezeigt 0.0 g 2. Prüfling auflegen, Stillstandsanzeige[ ] abwarten 40.8 g PRINT drücken, das Gesamtgewicht beider Prüflinge wird (Beispiel) angezeigt Vorgang beliebig oft wiederholen PLJ-GM-BA-d-1614...
TARE PRINT Mit 0.0 g Sekunden auswählen und mit bestätigen, „A…0.0“ wird angezeigt Prüfling auflegen, solange der Mittelwert gebildet wird, zeigt die Waage „-----„ an. 15.8 g Danach wird der Gewichtswert mit dem „OK“-Symbol an- gezeigt PLJ-GM-BA-d-1614...
Vortarierwert abgelegt werden soll TARE Mit 00000.0 bestätigen, „00000.0“ wird angezeigt, die erste Ziffer und das „NET“-Symbol blinken TARE PRINT tArE 1 Mit Vortarierwert eingeben und mit bestätigen, „tArE 1“ wird angezeigt Mit zurück in den Wägemodus PLJ-GM-BA-d-1614...
1 Mit Speicherplatz, unter dem der Vortarierwert hin- (Beispiel) terlegt wurde aufrufen PRINT -5.0 g Mit bestätigen, der Vortarierwert wird als negativer (Beispiel) Wert angezeigt Prüfling auflegen, das Nettogewicht des Prüflings wird 35.8 g angezeigt (Beispiel) PLJ-GM-BA-d-1614...
CntA Cntb TARE StAb Mit Datenausgabetyp auswählen� PRINT Mit 2.1.Pr_n wird die Einstellung übernommen, „2.1.PR_N“ erscheint SAVE? so oft drücken, bis „SAVE?“ erscheint PRINT 0.0 g Mit bestätigen, „0.0“ PLJ-GM-BA-d-1614...
Wert wird ange- (Beispiel) zeigt, die erste Ziffer blinkt 0030.00g TARE Mit Minimalgewicht eingeben (Beispiel) PRINT 2.2. S_Lo drücken, das Minimalgewicht wird übernommen. SAVE? so oft drücken, bis „SAVE?“ erscheint PRINT 0.0 g Mit bestätigen, „0.0“ PLJ-GM-BA-d-1614...
, gewünschte Baudrate auswählen� 9600 PRINT 2.3. bAud Mit bestätigen. SAVE? so oft drücken, bis „SAVE?“ erscheint PRINT 0.0 g Mit bestätigen, „0.0“ PRINT mehrmals drücken, bis Anzeige SAvE ? erscheint. Mit die vorgenomme- nen Änderungen abspeichern. PLJ-GM-BA-d-1614...
XX_ I CR LF Anweisung erhalten, kann aber nicht ausgeführt werden XX_^ CR LF Anweisung erhalten, aber time overflow Fehler aufgetreten XX_v CR LF Anweisung erhalten, aber Unterlast XX_E CR LF Fehler während der Ausführung, Zeitüberschreitung für stabilen Wägewert überschritten PLJ-GM-BA-d-1614...
Einheit Anzeiger zeichen zeichen zeichen Stabilitäts Anzeiger : Leerzeichen wenn stabil, ? wenn nicht stabil ^ wenn Überlast v wenn Unterlast Vorzeichen : Leerzeichen, wenn positiv Minuszeichen, wenn negativ Gewicht : 9 Zeichen, rechtsbündig Einheit : 3 Zeichen, linksbündig PLJ-GM-BA-d-1614...
Stabilitäts Anzeiger : Leerzeichen wenn stabil, ? wenn nicht stabil ^ wenn Überlast v wenn Unterlast Vorzeichen : Leerzeichen, wenn positiv Minuszeichen, wenn negativ Gewicht : 9 Zeichen, rechtsbündig Einheit : 3 Zeichen, linksbündig PLJ-GM-BA-d-1614...
Das Gerät darf nur von geschulten und von KERN autorisierten Servicetechnikern geöffnet werden. Vor dem Öffnen vom Netz trennen. 11.3 Entsorgung Die Entsorgung von Verpackung und Gerät ist vom Betreiber nach gültigem nationa- lem oder regionalem Recht des Benutzerortes durchzuführen. PLJ-GM-BA-d-1614...
• Es herrschen starke Temperaturschwankungen. • Die Anwärmzeit wurde nicht eingehalten. • Elektromagnetische Felder / Statische Aufladung (anderen Aufstellort wählen / falls möglich, stören- des Gerät ausschalten ) Beim Auftreten anderer Fehlermeldungen Waage aus- und nochmals einschalten. Bleibt Fehlermeldung erhalten, Hersteller benachrichtigen. PLJ-GM-BA-d-1614...
Page 58
Quecksilber, oder Pb = Blei) des für die Einstufung als schadstoffhaltig aus- schlaggebenden Schwermetalls versehen. Schadstoffarme Batterien nur mit einer durchgestrichenen Mülltonne. Die Rückgabemöglichkeit beschränkt sich auf Batterien der Art, die wir in unserem Sortiment führen oder geführt haben, sowie auf die Menge, deren sich Endverbrau- cher üblicherweise entledigen. PLJ-GM-BA-d-1614...
Page 60
KERN PLJ-GM Version 1.4 12/2016 Operating instruction Precision balance Table of Contents Technical data ....................4 Declaration of conformity ................5 Basic Information (General) ................6 Proper use ..........................6 Improper Use ..........................6 Warranty ............................ 6 Monitoring of Test Resources ....................7 Basic Safety Precautions ................
Humidity of air max. 80 % (not condensing) Underfloor weighing Standard hooks Housing (B x D x H) mm 210 x 335 x 88 Weighing plate (stainless steel) 128 x 128 195 x 195 Weight kg (net) 3.6 kg PLJ-GM-BA-e-1614...
2 Declaration of conformity To view the current EC/EU Declaration of Conformity go to: www.kern-sohn.com/ce The scope of delivery for verified weighing balances (= conformity- rated weighing balances) includes a Declaration of Conformity. PLJ-GM-BA-e-1614...
• The appliance is used outside the described uses • The appliance is modified or opened • mechanical damage and damage caused by media, liquids, natural wear and tear • The appliance is improperly set up or incorrectly electrically connected • The measuring system is overloaded PLJ-GM-BA-e-1614...
4.2 Personnel training The appliance may only be operated and maintained by trained personnel. 5 Transport and storage 5.1 Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage. PLJ-GM-BA-e-1614...
5.2 Packaging / return transport Keep all parts of the original packaging for a possibly required return. Only use original packaging for returning. Prior to dispatch disconnect all cables and remove loose/mobile parts. PLJ-GM-BA-e-1614...
Page 67
Secure all parts such as glass wind screen, weighing platform, power unit etc. against shifting and damage. Mains adapter Weighing pan (128 x 128 mm) Carrier weighing pan Weighing pan (195 x 195 mm) PLJ-GM-BA-e-1614...
(e.g. due to mobile phones or radio equipment), static electricity accumulations or instable power supply occur. Change location or remove source of interference. 6.2 Unpacking Carefully remove the balance from the packaging, remove plastic cover and setup balance at the intended workstation. PLJ-GM-BA-e-1614...
The accuracy of the balance depends on the local acceleration of gravity. Strictly observe hints in chapter Adjustment. 6.5.1 Stability display If the display shows the stability display [ ] the balance is in a stable status. If the status is instable the [ ] display disappears. PLJ-GM-BA-e-1614...
After the balance having performed a self check, automatic adjustment will start and in the display appears „CALib“ During the adjustment process „CAL-A“ is displayed If the adjustment process is finished, the balance will automatically return into weighing mode. PLJ-GM-BA-e-1614...
During the adjustment process „CAL-H“ is displayed If the adjustment process is finished, the balance will automatically return into the weighing mode. Use the button to cancel the adjustment process at any time. is briefly displayed. Then the balance returns automatically into weighing mode. PLJ-GM-BA-e-1614...
Balances with obligation to verify must be taken out of operation if: The weighing result of the balance is outside the error limit. Therefore, in regular intervals load balance with known test weight (ca. 1/3 of the max. load) and compare with displayed value. The reverification deadline has been exceeded. PLJ-GM-BA-e-1614...
• Never suspend loads that exceed the stated maximum load (max) (danger of breaking) Always ensure that there are no persons, animals or objects that might be damaged underneath the load. NOTICE After completing the underfloor weighing the opening on the bottom of the balance must always be closed (dust protection). PLJ-GM-BA-e-1614...
Button Function • Turn on/off • Function key (to select operating mode) Printout of the weighed value on an external PRINT appliance (printer or PC) Set weight display at zero Taring TARE Start manual adjustment TARE PLJ-GM-BA-e-1614...
Low battery level / battery charge status or damaged mains adaptor Net Balance is tared +/- tolerance with respect to reference weight entry of lower limit or weight below tolerance � 0.00 PLJ-GM-BA-e-1614...
Page 76
Stability test for internal adjustment CAL-H Manual internal adjustment CAL-A Automatic internal adjustment after switching on CAL-t Temperature-controlled internal adjustment CAL-C Time-controlled internal adjustment Abort Cancelling the internal adjustment process PLJ-GM-BA-e-1614...
Activating a changed parameter Confirm entry PRINT 8.2 Calling a menu / jumping back to weighing mode 8.2.1 Calling up menu Turn on balance by pressing PRINT Press simultaneously To go from P1.rEAD to P6.CAL in the menu press the repeatedly. PLJ-GM-BA-e-1614...
Your balance is ready to weigh as soon as the 0.00 g “0.00" display appears. Put on items to be weighed, weighed value is 19.68 g displayed. Wait until the stability display appears . Read the weighing value. To turn off the balance press PLJ-GM-BA-e-1614...
Press TARE Press anew Press to change selection� PRINT P3.1.StUn Setting will be imported by pressing the button. For this, press repeatedly until SavE ? appears on the display. PRINT Store changes carried out by pressing PLJ-GM-BA-e-1614...
The taring process can be repeated any number of times, e.g. when adding several components for a mixture (adding). The limit is reached when the whole weighing range is exhausted. After removing the taring container the total weight is displayed as negative display. PLJ-GM-BA-e-1614...
Weighing Units Funi Press Parts counting Press Tolerance weighing HiLo Press Percentage display by PrcA Press weighing Percentage display via Prcb Press manual default Auto-taring AtAr Press Peak value function Press � PLJ-GM-BA-e-1614...
Page 83
Is the parameter set to ALL in menu 4.1.FFun, access to the functions set to YES in the P4FFunc menu is available via the F key. However, if in menu 4.1.FFun one of the above parameters is selected, e. g. PcS, can merely be used to call just this particular menu item. PLJ-GM-BA-e-1614...
Please repeat this sequence of operations for any other operating mode available. 4.2.Funi 4.3.PcS 4.4.HiLo 4.5 PrcA 4.6 Prcb 4.7 AtAr 4.8 toP For this, press repeatedly until SavE ? appears on the display. Store changes PRINT carried out by pressing PLJ-GM-BA-e-1614...
To change your selection, press .� To change your selection, press PRINT 5.1.bl Setting will be imported by pressing For this, press repeatedly until SavE ? appears on the display. Store changes PRINT carried out by pressing PLJ-GM-BA-e-1614...
30 40 … 100 To change your selection, press no .� PRINT 5.2.blbA Setting will be imported by pressing For this, press repeatedly until SavE ? appears on the display. Store changes PRINT carried out by pressing PLJ-GM-BA-e-1614...
Selecting the menu item P5 othr TARE 5.1.bl Press Repeatedly press 5.3.bEEP until the following display appears TARE To change your selection, press .� To change your selection, press PRINT 5.3.bEEP Setting will be imported by pressing PLJ-GM-BA-e-1614...
2 seconds later� 0.00 g The balance returns to weighing mode after the charge status of the battery was shown. The display symbol (bat low) will be activated when the charge status of the battery drops below 18%. PLJ-GM-BA-e-1614...
P5 othr TARE 5.1.bl Press Repeatedly press 5.5. CHr6 until the following display appears TARE To change your selection, press .� To change your selection, press PRINT 5.5.CHr6 Setting will be imported by pressing PLJ-GM-BA-e-1614...
OFF 1 2 3 4 To change your selection, press .� PRINT 1.1.Fil Setting will be imported by pressing For this, press repeatedly until SavE ? appears on the display. Store changes PRINT carried out by pressing PLJ-GM-BA-e-1614...
To change your selection, press .� To change your selection, press PRINT 1.2 Auto Setting will be imported by pressing For this, press repeatedly until SavE ? appears on the display. Store changes PRINT carried out by pressing PLJ-GM-BA-e-1614...
Repeatedly press 1.3.tArA until the following display appears TARE AtAr To change your selection, press .� To change your selection, press .� tArF To change your selection, press PRINT 1.3.tArA Setting will be imported by pressing PLJ-GM-BA-e-1614...
TARE 1.1.Fil Press TARE Repeatedly press 1.4.Fnnd until the following display appears TARE To change your selection, press .� TARE To change your selection, press .� PRINT 1.4.Fnnd Setting will be imported by pressing PLJ-GM-BA-e-1614...
Confirm by pressing , „0.0“ appears and „PCS“ flashes Place the indicated quantity of pieces (Example) PRINT Acknowledge by (Example) Place the quantity of the pieces to be counted, the number of pieces will be displayed (Example) PLJ-GM-BA-e-1614...
Page 95
Back to weighing mode by pressing the button. If you select this function (press the F key) but no reference pieces are present on the weighing plate, the message –Lo- will appear briefly on the display and the balance’s display will return to weighing mode. PLJ-GM-BA-e-1614...
, „00000.0“ appears, the first digit flashes and „Min“ is displayed 2.0 g TARE Enter the minimum weight using (Example) PRINT Press 00000.0 , „00000.0“ appears, the first digit flashes and „Max“ is displayed 10.0 g TARE Enter the maximum weight using (Example) PLJ-GM-BA-e-1614...
Press repeatedly until “SAVE?“ appears PRINT 0.0 g Confirm by pressing , „0.0“ appears 00035.7 Press , the percent value entered as last is entered, (Example) the first digit flashes, the % symbol is displayed flashing PLJ-GM-BA-e-1614...
Press , place the weighing container, „------„ will be displayed briefly, then the balance changes automatically to the „0.0“ display and „NET“ will be displayed Place test item in weighing container, net weight value will be displayed. PLJ-GM-BA-e-1614...
, „0.0“ is displayed and the „Max“ symbol appears Place weight 123.4 g (Example) Place another weight 235.8 g (Example) The maximum weight will still be displayed even if all 235.8 g weight pieces have been removed (Example) PLJ-GM-BA-e-1614...
0.0 g Place the second test item and wait for the standstill display [ 40.8 g PRINT (Example) Press , the total weight of both test items is displayed Repeat the procedure as often as required PLJ-GM-BA-e-1614...
0.0 g PRINT pressing , „A…0.0“ will be displayed Place the test item; as long as the mean value is formed, the balance displays „-----„. 15.8 g After that the weight value is displayed with the „OK“ symbol PLJ-GM-BA-e-1614...
Acknowledge by 00000.0 , „00000.0“ appears, the first digit and the „NET“ symbol are flashing TARE Enter pretaring value by and confirm by tArE 1 PRINT pressing , „tArE“ will be displayed Return to weighing mode using PLJ-GM-BA-e-1614...
(Example) value has been stored PRINT -5.0 g Confirm by pressing , the pretaring value is (Example) displayed as negative value Place the test item, the net weight of the test item is 35.8 g displayed (Example) PLJ-GM-BA-e-1614...
CntA Cntb TARE StAb Use to select data output type� PRINT Setting will be imported by pressing 2.1.Pr_n „2.1.PR_N“ appears SAVE? Press repeatedly until “SAVE?“ appears PRINT 0.0 g Acknowledge by , „0.0“ PLJ-GM-BA-e-1614...
, the value entered as last is displayed, the first (Example) digit flashes 0030.00g TARE Enter the minimum weight using (Example) PRINT 2.2. S_Lo Press the button, the minimum weight will be imported. SAVE? Press repeatedly until “SAVE?“ appears PRINT 0.0 g Acknowledge by , „0.0“ PLJ-GM-BA-e-1614...
XX_ I CR LF Instruction received; impossible to carry out XX_^ CR LF Instruction received but time overflow error occurred XX_v CR LF Instruction received, but insufficient load XX_E CR LF Error during execution, timeout for stable weighing value exceeded PLJ-GM-BA-e-1614...
Space Presign Weight Space Unit indicator Stability indicator Space if stable, ? if not stable ^ if overload v if underload Sign: Space, if positive negative sign, if negative Weight: 9 signs, right justified Unit: 3 signs, left justified PLJ-GM-BA-e-1614...
(should be more than 3 seconds) „Err8“: Impossible to carry out taring / resetting „NULL“: Underload „FULL2“: Weighing range exceeded „LH“: Initial weight error Weight of weighing plate outside allowable tolerance of 10% „5-Full“: Display range exceeded upon totalising PLJ-GM-BA-e-1614...
The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. 11.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. PLJ-GM-BA-e-1614...
• Great fluctuations in temperature. • Warm-up time was ignored. • Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. PLJ-GM-BA-e-1614...
Page 114
KERN PLJ-GM Version 1.4 12/2016 Mode d'emploi Balance de précision Sommaire Caractéristiques techniques ................. 4 Déclaration de conformité ................5 Indications fondamentales (généralités) ............. 6 Utilisation conforme aux prescriptions.................. 6 Utilisation inadéquate ......................6 Garantie ............................. 6 Vérification des moyens de contrôle ..................7 Directives fondamentales de sécurité...
Page 115
Edition manuelle ........................54 9.6.3 Edition en continu ........................55 Messages d’erreur ..................56 Maintenance, entretien, élimination ............56 11.1 Nettoyage ..........................56 11.2 Maintenance, entretien......................56 11.3 Elimination ..........................56 Aide succincte en cas de panne ..............57 PLJ-GM-BA-f-1614...
80 % (non condensant) Installation de pesage en sous- oeillet d’accrochage Boîtier (larg x prof x haut) mm 210 x 335 x 88 Plateau de pesée (acier inox) 128 x 128 195 x 195 Poids kg (net) 3,6 kg PLJ-GM-BA-f-1614...
2 Déclaration de conformité Vous trouvez la déclaration de conformité CE- UE actuelle online sous: www.kern-sohn.com/ce Dans le cas de balances étalonnées (= de balances à la conformité évaluée) la déclaration de conformité est comprise dans les fournitures. PLJ-GM-BA-f-1614...
• de modification ou d´ouverture de l´appareil • endommagement mécanique et d´endommagement lié à des matières ou des liquides, détérioration naturelle et d´usure • de mise en place ou d´installation électrique inadéquates • de surcharge du système de mesure PLJ-GM-BA-f-1614...
L´appareil ne doit être utilisé et entretenu que par des collaborateurs formés à cette fin. 5 Transport et stockage 5.1 Contrôle à la réception de l´appareil Nous vous prions de contrôler l´emballage dès son arrivée et de vérifier lors du déballage que l´appareil ne présente pas de dommages extérieurs visibles. PLJ-GM-BA-f-1614...
Conservez tous les éléments de l’emballage d’origine en vue d’un éventuel transport en retour. L´appareil ne peut être renvoyé que dans l´emballage d´origine. Avant expédition démontez tous les câbles branchés ainsi que toutes les pièces détachées et mobiles. PLJ-GM-BA-f-1614...
Page 121
Calez toutes les pièces p. ex. pare-brise en verre, plateau de pesée, bloc d’alimentation etc. contre les déplacements et les dommages. Adaptateur réseau Plateau de pesée (128 x 128 mm) Vecteur de plateau de pesée Plateau de pesée (195 x 195 mm) PLJ-GM-BA-f-1614...
Il faut alors changer de site ou éliminer la source parasite. 6.2 Déballage Sortir avec précaution la balance de l’emballage, retirer la pochette en plastique et installer la balance au poste de travail prévu à cet effet. PLJ-GM-BA-f-1614...
Avant le raccordement ou le débranchement d´appareils supplémentaires (imprimante, PC) à l´interface de données, la balance doit impérativement être coupée du secteur. N´utilisez avec votre balance que des accessoires et des périphériques livrés par KERN, ces derniers étant adaptés de manière optimale à votre balance. PLJ-GM-BA-f-1614...
Ce processus d´ajustage doit être effectué à chaque première mise en service et après chaque changement de lieu d´installation et à fluctuations du température d’environs. Pour obtenir des valeurs de mesure précises, il est recommandé en supplément d´ajuster aussi périodiquement la balance en fonctionnement de pesée. PLJ-GM-BA-f-1614...
Lorsque la température fluctue de 3 °C la balance annonce par l’affichage „CALib“ l’ajustage interne: La balance démarre le processus d’ajustage et affiche „CAL-t“. Si le processus d’ajustage est terminé, la balance se replace automatiquement en mode de pesée. PLJ-GM-BA-f-1614...
Si le processus d’ajustage est terminé, la balance se replace automatiquement en mode de pesée. La touche permet d’abandonner la fonction d’ajustage à tout moment. est brièvement affiché. Après la balance change automatiquement dans le mode de pesée. PLJ-GM-BA-f-1614...
2 ans en règle générale. Les prescriptions légales du pays d´utilisation doivent être respectées. Après la procédure d’étalonnage on apposera des scellés sur la balance aux endroits marqués. L’étalonnage de la balance n’est pas valide sans l’apposition des „scellés“. PLJ-GM-BA-f-1614...
Page 128
Chargez de ce fait à intervalles réguliers la balance avec un poids de contrôle connu (env. 1/3 de la charge max.) et comparez le résultat avec la valeur affichée. L’échéancier pour l’étalonnage périodique est dépassé. PLJ-GM-BA-f-1614...
Veillez toujours, à ce qu’il n’y ait pas d’être vivant ou d’objet sous la charge, qui risquerait d’être lésé ou endommagé. REMARQUE! A la fin du pesage en sous-sol, il faut obligatoirement refermer la trappe dans le fond de la balance (protection contre la poussière). PLJ-GM-BA-f-1614...
• Mise en marche / arrêt • Touche fonctionnelle (sélection du régime de fonctionnement) • Edition d’une valeur pondérale sur un appareil PRINT externe (imprimante ou PC) • Mise à zéro de l’affichage du poids • Tarage TARE • Démarrer l’ajustage manuel TARE PLJ-GM-BA-f-1614...
• La valeur affichée est stable • PCS • Affichage en mode de fonctionnement „comptage des pièces“ • kg (g) • Affichage en mode de fonctionnement „pesée“ • Faible niveau d’accu / état de charge de l’accu ou • adaptateur réseau endommagé PLJ-GM-BA-f-1614...
Page 132
• Ajustage manuel interne • CAL-A • Ajustage manuel interne après la mise en marche • CAL-t • Ajustage interne en fonction de la température • CAL-C • Ajustage interne en fonction du temps • Abort • Interruption du processus d’ajustage interne PLJ-GM-BA-f-1614...
P5 othr 5.1 bL Auto Eclairage d’arrière-plan 5.2 blbA Intensité de l’éclairage de l'arrière-plan 5.3 bEEP Son des touches 5.4 t1 Mise hors circuit automatique 5.5 CHr6 Mise hors circuit du contrôle des accus P6 CAL 6.4 CA-r non documenté PLJ-GM-BA-f-1614...
8.2 Appel du menu / retour en mode de pesée 8.2.1 Appel du menu Mettez la balance en marche sur PRINT Appuyez en même temps sur et sur Appuyez plusieurs fois sur pour accéder dans le menu de P1.rEAD à P6.CAL. PLJ-GM-BA-f-1614...
0.00 g balance est prête à peser. Y déposez l’objet à peser, la valeur pesée est 19.68 g affichée. Attendre que apparaisse l’affichage de stabilité . Lecture de la valeur pesée. Pour mettre la balance hors circuit, appelez PLJ-GM-BA-f-1614...
Appuyer sur pour changer la sélection.� PRINT P3.1.StUn Le nouveau réglage est repris par appel de A cet effet il faut appuyer plusieurs fois sur jusqu’à ce que l’affichage SAvE ? PRINT apparaisse. Mémorisez les modifications apportées sur PLJ-GM-BA-f-1614...
La procédure de tarage peut être répétée à volonté, par exemple pour le pesage de plusieurs composants constituant un mélange (ajout). La limite est atteinte, lorsque toute la gamme de pesage est sollicitée. Une fois le contenant de tare enlevé, le poids total apparaît en affichage négatif. PLJ-GM-BA-f-1614...
F, qui sont libérés dans le menu 4.2 à 4.8 Unités de pesage Funi Appuyer sur Comptage de pièces Appuyer sur Pesée avec tolérance HiLo Appuyer sur Affichage du PrcA Appuyer sur pourcentage par pesée PLJ-GM-BA-f-1614...
Page 139
P4 Func sont associées à YES. Si dans le menu 4.1.FFun est par contre sélectionné un des paramètres ci-dessus p. ex. PcS, ne permet d’appeler que ce point du menu en particulier. PLJ-GM-BA-f-1614...
Répétez ce processus pour chaque autre mode de fonctionnement. 4.2.Funi 4.3.PcS 4.4.HiLo 4.5 PrcA 4.6 Prcb 4.7 AtAr 4.8 toP A cet effet il faut appuyer plusieurs fois sur jusqu’à ce que l’affichage SAvE ? PRINT apparaisse. Mémorisez les modifications apportées sur PLJ-GM-BA-f-1614...
Appuyer sur � pour modifier la sélection PRINT 5.1.bl Le nouveau réglage est repris par appel de A cet effet il faut appuyer plusieurs fois sur jusqu’à ce que l’affichage SAvE ? PRINT apparaisse. Mémorisez les modifications apportées sur PLJ-GM-BA-f-1614...
no � pour modifier la sélection� PRINT 5.2.blbA Le nouveau réglage est repris par appel de A cet effet il faut appuyer plusieurs fois sur jusqu’à ce que l’affichage SAvE ? PRINT apparaisse. Mémorisez les modifications apportées sur PLJ-GM-BA-f-1614...
Appuyer sur Appuyez plusieurs fois sur �jusqu’à ce 5.3.bEEP qu’apparaisse l’affichage suivant TARE Appuyer sur pour modifier la sélection� Appuyer sur � pour modifier la sélection PRINT 5.3.bEEP Le nouveau réglage est repris par appel de PLJ-GM-BA-f-1614...
1 seconde après 2 secondes après� 0.00 g Après avoir affiché l’état de charge de l’accu, la balance retourne en mode de pesée. Le symbole d’affichage (bat low) est activé, lorsque l’état de charge de l’accu n’atteint plus 18 %. PLJ-GM-BA-f-1614...
Appuyez plusieurs fois sur �jusqu’à ce 5.5. CHr6 qu’apparaisse l’affichage suivant TARE Appuyer sur pour modifier la sélection� Appuyer sur � pour modifier la sélection PRINT 5.5.CHr6 Le nouveau réglage est repris par appel de PLJ-GM-BA-f-1614...
Appuyer sur � pour modifier la sélection� PRINT 1.1.Fil Le nouveau réglage est repris par appel de A cet effet il faut appuyer plusieurs fois sur jusqu’à ce que l’affichage SAvE ? PRINT apparaisse. Mémorisez les modifications apportées sur PLJ-GM-BA-f-1614...
Appuyer sur � pour modifier la sélection PRINT 1.2.Auto Le nouveau réglage est repris par appel de A cet effet il faut appuyer plusieurs fois sur jusqu’à ce que l’affichage SAvE ? PRINT apparaisse. Mémorisez les modifications apportées sur PLJ-GM-BA-f-1614...
TARE AtAr Appuyer sur pour modifier la sélection� Appuyer sur � pour modifier la sélection� tArF Appuyer sur � pour modifier la sélection PRINT 1.3.tArA Le nouveau réglage est repris par appel de PLJ-GM-BA-f-1614...
Appuyer sur Appuyez plusieurs fois sur �jusqu’à ce 1.4.Fnnd qu’apparaisse l’affichage suivant TARE Appuyer sur pour modifier la sélection� Appuyer sur � pour modifier la sélection� PRINT 1.4.Fnnd Le nouveau réglage est repris par appel de PLJ-GM-BA-f-1614...
, „FREE“ ou „10“ ou „20“ ou „50“ apparaît (exemple) Sélectionner sur la quantité de référence voulue. (exemple) PRINT 0.0 g Valider sur , „0.0“ apparaît et „PCS“ clignote Mettre la quantité de pièces sélectionnée (exemple) PLJ-GM-BA-f-1614...
Page 151
Si cette fonction est appelée (la touche F est enclenchée ), mais qu’il n’y a pas de pièces de référence sur le plateau de pesée, apparaît brièvement –Lo- sur l’afficheur et l’affichage de la balance retourne en mode de pesée. PLJ-GM-BA-f-1614...
„Min“ est affiché 2,0 g TARE Saisir le poids minimum sur (exemple) PRINT Confirmer sur 00000,0 , „00000.0“ apparaît, le premier chiffre clignote et „Max“ est affiché 10.0 g TARE Saisir le poids maximum sur (exemple) PLJ-GM-BA-f-1614...
„PrcA“ apparaisse clignotant TARE Appuyer sur 4.1.FFun SAVE? Appuyer sur jusqu’à ce que „SAVE ?“ apparaît PRINT 0.0 g Valider sur , „0.0“ apparaît Appuyer sur , „0.0“ apparaît, et % est affiché PLJ-GM-BA-f-1614...
0.0 g Valider sur , „0.0“ apparaît 00035.7 Appuyer sur la valeur de pourcentage saisie comme dernière est affichée, le premier chiffre clignote, le (exemple) symbole % s’affiche clignotant TARE 40.0 % Saisir le poids référentiel sur PLJ-GM-BA-f-1614...
Appuyer sur , déposer le récipient à peser, „------„ sera brièvement affiché, après la balance changera automatiquement à l’affichage „0.0“ et „NET“ est affiché Posez les pièces à peser dans le récipient à peser, le poids net sera affiché PLJ-GM-BA-f-1614...
, „0.0“ est affiché et le symbole „Max“ est affiché Mettre le poids 123.4 g (exemple) Déposer un nouveau poids 235.8 g (exemple) Même si toutes les pièces de poids sont ôtées, le poids 235.8 g maximal reste affiché (exemple) PLJ-GM-BA-f-1614...
Mettre la deuxième pièce d’essai et attendre l’affichage de la stabilité [ 40.8 g PRINT (exemple) Appuyer sur , le poids total des deux pièces d’essai est affiché Répéter la procédure autant de fois que souhaité PLJ-GM-BA-f-1614...
0.0 g PRINT , „A…0.0“ est affiché Mettre la pièce d’essai, pendant que la valeur moyenne soir formée, la balance affichera „-----„ . 15.8 g Après est affichée la valeur de poids avec le symbole „OK“ PLJ-GM-BA-f-1614...
, „00000,0“ apparaît, le premier chiffre clignote et le symbole das „NET“ sont affichés TARE Saisir la valeur de pré-tarage sur et valider tArE 1 PRINT , „tArE 1“ est affiché Sur retourner dans le mode de pesée PLJ-GM-BA-f-1614...
(exemple) pré-tarage a été enregistrée PRINT -5.0 g Valider sur , la valeur de pré-tarage est affichée (exemple) comme valeur négative Mettre la pièce d’essai, le poids net de la pièce d’essai est 35.8 g affiché (exemple) PLJ-GM-BA-f-1614...
CntA Cntb TARE StAb � PRINT Le réglage est repris par appel de 2.1.Pr_n , „2.1.PR_N“ apparaît SAVE? Appuyer sur jusqu’à ce que „SAVE ?“ apparaît PRINT 0.0 g Confirmer sur , „0.0“ PLJ-GM-BA-f-1614...
Saisir le poids minimum sur (exemple) PRINT 2.2. S_Lo Appuyer sur la touche , le poids minimal est repris. SAVE? Appuyer sur jusqu’à ce que „SAVE ?“ apparaît PRINT 0.0 g Valider sur , „0.0“ PLJ-GM-BA-f-1614...
„SAVE ?“ apparaît PRINT 0.0 g Valider sur , „0.0“ A cet effet il faut appuyer plusieurs fois sur la touche F jusqu’à ce que l’affichage SAvE ? apparaisse. Mémorisez les modifications apportées sur la touche PRINT. PLJ-GM-BA-f-1614...
Consigne reçue, ne pouvant pas être exécutée XX_^ CR LF Consigne reçue, mais erreur time overflow intervenue XX_v CR LF Consigne reçue, mais charge insuffisante XX_E CR LF Erreur en cours d’exécution, dépassement dans le temps pour valeur de pesée stable PLJ-GM-BA-f-1614...
Affichage de la stabilité : Signe espace pour stable, ? pour instable ^ pour surcharge v pour charge insuffisante Signe : Signe espace, pour positif Signe moins, pour négatif Poids: 9 caractères, cadrés à droite Unité: 3 caractères, cadrés à gauche PLJ-GM-BA-f-1614...
Affichage de la stabilité : Signe espace pour stable, ? pour instable ^ pour surcharge v pour charge insuffisante Signe : Signe espace, pour positif Signe moins, pour négatif Poids: 9 caractères, cadrés à droite Unité: 3 caractères, cadrés à gauche PLJ-GM-BA-f-1614...
L´appareil ne doit être ouvert que par des dépanneurs formés à cette fin et ayant reçu l´autorisation de KERN. Avant d´ouvrir l´appareil, couper ce dernier du secteur. 11.3 Elimination L´élimination de l´emballage et de l´appareil doit être effectuée par l´utilisateur selon le droit national ou régional en vigueur au lieu d´utilisation. PLJ-GM-BA-f-1614...
• Le temps de préchauffage n’a pas été respecté. • Champs électromagnétiques/ charge électrostatique (changer de lieu d´installation/ si possible, arrêter l´appareil provoquant l´anomalie) Au cas où d´autres messages d´erreur apparaissent, arrêter puis rallumer la balance. En cas de perduration du message d’erreur, faites appel au fabricant. PLJ-GM-BA-f-1614...