CONTROLLO PRE-INSTALLAZIONE
I
Le ante devono essere solidamente fissate ai cardini delle colonne, non
devono flettere durante il movimento e devono muoversi senza attriti.
Prima d'installare l'IDRO è meglio verificare tutti gli ingombri necessari per poterlo
installare.
Se il cancello si presenta come da Fig. 1 non occorrono modifiche.
È obbligatorio uniformare le caratteristiche del cancello alle norme e leggi vigenti. La
porta può essere automatizzata solo se in buono stato e se rispondente alla norma EN
12604.
- L'anta non deve presentare porte pedonali. In caso contrario occorrerà prendere
opportune precauzioni in accordo al punto 5.4.1 della EN12453 (ad esempio impedire il
movimento del motore quando il portoncino è aperto, grazie ad un microinterruttore
opportunamente collegato in centralina).
- Non bisogna generare punti di intrappolamento (ad esempio tra anta aperta del
cancello e cancellata).
Non devono essere presenti fermi meccanici al di sopra del cancello perché non sono
sufficientemente sicuri.
CONTROLE PRE-INSTALLATION
F
Le portail à battant doit être solidement fixé aux cardans des colonnes,
ne doit pas flechir pendant le mouvement et doit pouvoir manoeuvrer sans effort.
Avant d'installer le IDRO, il convient de verifier tous les encombrements necessaires
pour procéder à l'installation.
Si le portail se presente comme indiqué Fig. 1, aucune modification n'est necessaire.
Il est impératif d'uniformiser les caractéristiques du portail avec les normes et les lois en
vigueur. La porte peut être automatisée seulement si elle est en bon état et qu'elle est
conforme à la norme EN 12604.
- Le vantail ne doit pas comporter de portillon intégré. Dans le cas contraire, il sera
opportun de prendre les précautions décrites au point 5.4.1 de la EN 12453 (interdire,
par le biais d'un contact raccordé aux bornes adaptées de la platine électronique, la
mise en marche de l'automatisme si le portillon est ouvert).
- Ne pas générer de zone d'écrasement (par exemple entre le vantail ouvert et la
cloture).
Il ne devra y avoir aucun arrêt mécanique au-dessus du portail, étant donné que les
arrêts mécaniques ne sont pas suffisamment sûrs.
PRE-INSTALLATION CHECKS
GB
The leaf must be fixed firmily on the hinges to the pillars, must not be
flexible during the movement and must move without frictions.
Before the installation of IDRO, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in Fig. 1.
Gate features must be uniformed with the standards and laws in force. The door/gate
can be automated only if it is in a good condition and its conditions comply with the EN
12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the opposite case it
is necessary to take the appropriate steps, in accordance with EN 12453 norm (for
instance; by preventing the operation of the motor when the pedestrian opening is
opened, by installing a safety microswitch connected with the control panel).
No mechanical stop shall be on top of the gate, since mechanical stops are not safe
enough.
PRÜFUNG VON DER MONTAGE
D
Das Flugeltor muß fest an der Angelpunkten der Trager fixiert sein, darf
sich wahrend der Bewegung nicht biegen und ohne reibung nicht bewegen.
Bevor IDRO montiert wird ist es besser alle Hindernisse, die bei der Montage auftreten
konnen festzustellen.
Bei einem Tor wie in Abbildung 1 mussen keine Veranderungen vorgenommen werden.
Es ist erforderlich, die Charakteristiken des Tors an die geltenden Normen und Gesetze
anzupassen. Das Tor kann nur automatisch Angeschlossen werden, wenn es in einem
einwandfreien Zustand ist und der EN12604 entspricht.
- Das Tor welches keine Gehfluegelfunktion hat,in diesem Fall ist es erforderlich das Tor
mit der norm EN12453 in Einklang zu bringen(z.B. das in Bewegung setzen des Motors
per Handsender, wenn der Gehfluegel geoeffnet ist. Das zu vehindern koennen sie
einen Endschalter anschliessen der beim oeffnen des Gehfluegel andere
automatischen funktionen ausser Kraft setzt).
Es dürfen keine mechanischen Anschläge über dem Tor vorhanden sein, da diese nicht
ausreichend sicher sind.