Before each fault clearance
Switch off device
Wait for stop of saw
Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Machine fails to start after
switching on or switches off
during idle running
Motor hums, but does not initiate Condenser defect
Machine stops while cutting
Work piece jams when pushing
forward or pulling backward
Burn marks at the cut edges
Saw band breaks
Saw band contorted
Saw band runs out of cutting line
or passes of
Saw vibrates
Sawdust exit blocked
Saw band does not move
although motor is running
24
Possible faults
Possible cause
Power failure
Extension cable defect
Motor or switch defect
Doors not locked
Saw band edgeless
Feed too large
Saw band edgeless
The parallel stopper is not parallel to the saw
band
Saw band is not suitable for the work step or
edgeless
Wrong saw stressing
To high load
Wrong saw band
To high lateral load
Saw band does not run centrally on the upper
band saw roll
Insufficient fixation
Saw table loose
Fixation screws of motor lose
No extraction system connected
Extraction power to weak
Drive belt lose
Drive belt defect
Removal
Check safety fuse
Check cable, no longer use defect cable
Have motor or switch checked by an
approved electrician or replaced by original
spare parts
Close and lock the doors
Condenser should be replaced by customer
service
Replace saw band
Allow the motor to cool off and then continue
work using less pressure
Hold the work piece firmly and switch off the
motor immediately. Then renew the saw
band.
Readjust the parallel stopper.
Replace saw band
Adjust saw band stress
Reduce pressure against the saw band.
Wrong saw band
thin work piece = small saw band
thick work piece = broad saw band
Avoid lateral pressure on the saw band.
Adjust incline of the upper band saw roll
Fix saw on suitable ground
Adjust and fix saw table
Fasten fixation screws
Switch off saw, remove sawdust and
connect extraction system
Switch off saw, remove sawdust and
increase extraction power (air speeds 20
m/sec on suction socket of sawdust.
Clamp drive belt
Replace drive belt