Storage
Remove the mains plug from the socket.
Store unused equipment in a dry, locked place out of the
reach of children.
Before extended storage, please observe the following to
increase the service life of the device and to ensure smooth
operation:
thoroughly clean the saw
treat all movable parts with an environmentally friendly oil
Never use any grease!
Possible faults
Before each fault clearance
Switch off device
Wait for standstill of the saw blade
Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Machine fails to start after
switching on or switches off
during idle running
No crosscut function
Saw blade jams while cutting
Burned spots at the cut areas
Saw vibrates
Chip outlet is clogged
Rotary table moves hard
Possible cause
Power failure
Extension cable defect
Motor or switch defect
Transport locking pin not removed
Locking device for pendulum cover not opened
Saw blade is dull
Feed is too great
Saw blade is not suitable for the work step or is
dull
Saw blade is warped
Saw blade not properly mounted
No exhaust system connected
Exhaust power too weak
Chips under rotary table
Guarantee
Please observe the enclosed terms of guarantee.
Removal
Check safety fuse
Check cable, no longer use defect cable
Have motor or switch checked by an
approved electrician or replaced by original
spare parts
Pull out transport locking pin (5)
Open locking device (17)
Replace saw blade (36)
Allow motor to cool and proceed working with
less pressure
Replace saw blade
Replace saw blade
Mount saw blade properly
Switch off saw, remove chips and connect
exhaust system
Switch off saw, remove chips and increase
exhaust power (air velocity 20 m/sec at chip
exhaust neck.
Remove chips