10. Guidelines
RCS-EX
The test results show that the devices fulfil the test specifications for
simple electrical equipment and therefore do not fall under explosion
protection directives 2014/34/EU. By limiting voltage to maximum 30V,
Low Voltage Directive does not apply.
RCS
Devices of type RCS fall under Low Voltage Directive.
11. Temperature class table
Ambient
temperature in
the connection
area
Up to 80°C
Below 125°C
The values specified are maximum values. The effective, permitted values
are to be taken from the type plate.
MoWa OLS10-Z-x 4573340 fr web
Ambient and
liquid temperature
in the float area
In the connection
Up to 68°C
Below 125°C
Surface temperature and
temperature class T
In the float
area
80°C T6
80°C T6
125°C T4
130°C T4