74
• Cutsresulting from the crossing of the connecting lead.
• Insulation damages caused by the ripping out of the
connecting lead from the wall socket.
• Cracks due to the ageing of the insulation.
Faulty electrical connecting leads such as these may not
be used and are highly dangerous due to the insulation
damage.
Check electrical connecting leads regularly for damage.
Ensure that the connecting lead is not attached to the
mains supply when you are checking it.
Electrical connecting leads must correspond to the rele-
vant VDE and DIN regulations. Only use connecting leads
with the code H 07 RN. The type designation must be
printed on the connecting lead by regulation.
Single-phase motor
• The supply voltage must be 230 volt – 50 Hz.
• Extension leads up to 25 m in length must have a
cross-section of 1.5 mm
length is over 25 m must have a cross-section of at
least 2.5 mm
.
2
• The mains connection is fused with a 16 A slow-blow
fuse.
Connections or repairs on the electrical equipment may
only be carried out by an electrician.
Please give the following information if you have any en-
quiries.
• Motor manufacturer
• Kind of current
• Machine type label data
If your are sending back the motor, always send the com-
plete drive unit with the switch.
Maintenance
Warning: Turn off the machine and disconnect from the
power supply before conducting maintenance work or set-
tings.
Store the manual close to the machine.
Keep the machine clean.
Wear goggles when cleaning the machine.
Caution: Do not clean synthetic components of the bench
using aggressive cleaning agents. We recommend a mild
dish washing liquid. The machine must not get into con-
tact with water.
• Check the saw blade regularly. Use only well-sharp-
ened, crack-free and not distorted saws. Use only tools
that comply with the European standard EN 847-1.
• Exchange immediately table lining that run out.
• Always keep table surface nonresinous.
• Clean regularly the inner section of the machine, like
tooth segement and pinion of the oscillating device, of
wood and chip rests.
• Remove possible sawdust blockages at the discharge.
. Extension leads whose