INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
5.3 REPLACEMENT OF THE LIFT LEVER SPRINGS
ATTENTION: Make sure that the coupling is closed, ie. the coupling pin
(14) is down.
1)
Remove the 3 screws (21) keeping the washers, remove the mechanism unit
(20a);
2)
Remove the self-locking nut (26), the washer (27), the spacer (28) and the
sealing washer (30).Remove from the mechanism unit (20a)
The operating handle (22A-22B) keeping the springs (17a 17b) (see chapter 7
DISPOSAL, page 30/32) and the lift lever (15);
3)
Fit the lift lever (15) in the mechanism unit (20a) making sure that the eyelets of
the new springs (17a-17b) engage with the pins on each side of the lift lever
(15);
4)
Refit the operating handle (22A-22B). Mount the sealing washer (30), spacer
(28), washer (27) and tighten the self-locking nut (26);
5)
Replace the mechanism unit (20a) (see point 3 in chapter 5.2 REPLACEMENT
OF THE MECHANISM UNIT AND OF THE COUPLING PIN, page 22/32).
30
28
27
26
DRAWBAR COUPLING E 40
14
15
17a
21
PAG.
23/32
CHAP . 5
REV. 00
22A 22B
20a
17b