Axioscope 5/7/Vario
HBO 100 W power supply unit
Range of application ..................................................................................................................... indoor
Protection class ...................................................................................................................................... I
Protection type ................................................................................................................................ IP 20
Mains voltage ........................................................................................................ 100 VAC ... 240 VAC
..............................................................................................................
Mains frequency ................................................................................................................... 50 ... 60 Hz
Power consumption with HBO 103 in operation............................................................................ 155 VA
Fuses in accordance with IEC 127
Axioscope 5/7 microscope stand for LED illumination in transmitted light: .............. 2 T 3.15 A/H, 5x20 mm
Axioscope 5/7 microscope stand for HAL 50 illumination in transmitted light: ....... 2 T 3.15 A/H, 5x20 mm
HBO 100 W power supply unit ................................................................................ T 2.0 A/H, 5x20 mm
12 V DC 100 W external power supply unit ............................................................2 T 5.0 A/H, 5x20 mm
Light sources
LED illumination transmitted light/reflected light
Power consumption ............................................................................................................ max. 10 W
Adjustment of light source ............................................................... continuous approx. 10 to 800 mA
Halogen lamp ......................................................................................................................... 12 V/50 W
Adjustment of light source ..................................................... infinitely variable from approx. 3 to 12 V
Halogen lamp ....................................................................................................................... 12 V/100 W
Adjustment of light source ..................................................... infinitely variable from approx. 3 to 12 V
Mercury vapor short arc lamp ............................................................................................. HBO 103 W/2
Power consumption for HBO 103 W/2 ...................................................................................... 100 W
Axioscope 5/7/Vario
Stand with manual/motorized stage focusing
Coarse drive .................................................................................................... approx. 4 mm/rotation
Fine drive .......................................................... approx. 0.4 mm/rotation; approx. 4 µm scale intervals
Lifting range................................................................................................................ approx. 25 mm
Height stop ........................................................................................................ mechanically variable
Condenser 0.9/1.25 H with optional
modulator disk ...................................................................................... for bright-field, dark-field and
.........................................................................................................
Manual objective change ...................................................................... via nosepiece, 6x, M27, encoded
Manual reflector module change .............................................................. via reflector slider 2x encoded,
...............................................................................................
07/2018
TECHNICAL DATA
430035-7014-111
No voltage adjustment required
phase contrast 1, 2, 3 or PlasDIC
reflector turret 4x encoded or 6x encoded