USER U/I menu,
refresh charging
settings
User U/I menu
3.
Exit
PRESET menu
(preferred set-
tings)
Important! to avoid damage to the vehicle electronics, the following modes cannot be
saved:
-
1.
2.
Set refresh charging voltage (setting range: 12.0 - 17.0 V)
-
Press Start/Stop button
-
Adjust refresh charging voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Set refresh charging period (setting range: 2 - 30h)
-
Press Start/Stop button
-
Adjust refresh charging period in 10 minute steps
-
Press Start/Stop button to confirm setting
Press Start/Stop button to exit
Refresh charging
Open the Preset menu
Select an option from the preset menu
Preferred Setting Used Mode (factory setting):
After disconnecting the charging terminals or mains supply, the last mode se-
lected is saved.