Additional Boundary Wire
We recommend the use of 20 gauge insulated multi-strand copper
wire for direct burial. Extra Boundary Wire can be purchased in 150 m
(500 ft) spools at the store where you purchased the kit or through the
Customer Care Centre.
Note: When adding Boundary Wire, it must act as a continuous loop.
The table at right indicates the approximate length of Boundary Wire
needed for a rectangular, Single Loop layout. Length will vary due to
the amount of twisted wire and layout used.
__________________________________________________

Connect the Wires to the Fence Transmitter

Step
4
Boundary Wire
1. Run the Boundary Wire to the Fence Transmitter through a window, under
a door, through a crawl space vent, or any other appropriate available access.
You can also drill a hole through your wall.
2. Strip the ends of the Boundary Wire approximately 1.3 cm (1/2 in).
3. Insert the Boundary Wires into the Boundary Wire Terminals on the Fence
Transmitter.
4. Turn the Boundary Width Control knob to 10. This will set the Warning Zone
at the maximum width.
5. Plug the Power Adapter into the Power Jack and a working outlet.
6. The Power Light and Loop Indicator Lights should come on. If this does not
happen, see the "Troubleshooting" section.
__________________________________________________

Prepare the Receiver Collar

Step
5
Your Receiver Collar comes with short Contact Points installed. Use the long Contact Points for cats with long or
thick hair. Tighten the Contact Points with pliers one-half turn beyond finger tight (5A). Check the tightness weekly.
To Insert and Remove the Batteries
1. With a coin, unlock the Battery Door and remove it (5B).
2. Insert two 3-volt Lithium (CR2032 batteries) into the Battery Door (5B).
3. Place the Battery Door back into the Receiver (5C).
4. With a coin, slide Battery Door latch to lock it (5C).
Replacement batteries
(3-volt, CR2032) can
be found at many
retailers. Contact the
Customer Care Centre
or visit our website at
www.petsafe.net for a
list of common retailers.
8
(4A)
5A
2
2
3
3
www.petsafe.net
Area to be
enclosed
Ares
10
13
20
40
80
200
400
600
800
900
5B
Approximate wire
length required
Acres
Metres
Feet
1/4
127
415
1/3
146
480
1/2
180
590
1
255
835
2
360
1180
5
570
1870
10
800
2600
15
1000
3200
20
1100
3700
22
1200
4000
4A
}
Boundary Wire
Terminals
Loop Indicator
Light
Power Light
Power
Boundary Width
Jack
Control