Logic
Definition
Configuration
of EXPI2 input
on input-output
EXPI2
expansion
board.
1-3
Configura-
tion of EXPO2
output
on input-output
EXPO1
expansion
board
4-5
Configura-
tion of EXPO2
output
on input-output
EXPO2
expansion
board
6-7
Traffic light pre-
TRAFFIC LIGHT
flashing
PREFLASHING.
TRAFFIC LIGHT
Steadily lit red
RED LA P
light
ALWAYS ON
*
Only active on FW ≥ 2.10
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
Associates the desired key with the 2nd radio channel command. If no output is configured as 2nd Radio Channel Output, the 2nd radio channel
add 2ch
controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
32 -
DEIMOS ULTRA BT A 400 - DEIMOS ULTRA BT A 600
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
0
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the mo-
*
11
vement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the mo-
*
12
vement stops.
0
Output configured as 2
1
Output configured as SCA (gate open light).
11
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
11
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
Output configured as Traffic Light control with TLB board.
11
0
Pre-flashing switched off.
0
1
Red lights flash, for 3 seconds, at start of operation.
0
Red lights off when gate closed.
0
Red lights on when gate closed.
1
Optional extras
nd
Radio Channel.