Main applications
• Plastic extrusion lines and
injection presses
• Packing and packaging
machines
• Polymerization and
production plants for
synthetic fibers
• Rubber vulcanization plants
• Driers for ceramics and
construction elements
• Chemical and
pharmaceutical industry
• Industrial electric furnaces
• Food processing plants
GENERAL
Turning an electric load on or off
requires the use of a suitable
interrupt and protection device that is
safe and immune to disturbances.
In addition, for optimum process
control in many industrial
applications, it is indispensable to
drive the load with very short
switching times: the best solution is
the use of solid state relays.
Gefran proposes the GTS range of
power solid state relays with voltage
zero crossing, currents from 10A to
120A, and rated voltages of 230VAC
and 480VAC.
Versions with TRIAC and with double
SCR are available.
All models are designed to
guarantee operation at rated
currents, with continuous driving of
power at 40°C working temperature.
For less critical operating
conditions, you can use the
products beyond rated currents
(using the dissipation curves as
reference).
Various accessories are available,
such as the attachment for panel
fastening, fuses and fuse holders.
GTS-T 10 / 20; GTS 15 / 25 / 40 / 50 / 60 / 90 / 120A
POWER SOLID STATE RELAYS WITH LOGIC CONTROL

TECHNICAL DATA

General features
Category of use: AC1
Rated working voltage
- 230Vac (max. range 24...280Vac)
- 480Vac (max. range 24...530Vac)
Rated frequency: 50/60Hz
Non-repetitive voltage:
• 500Vp for model with rated voltage
230Vac
• 1200Vp for model with rated
voltage 480Vac
Switching voltage for zero: < 20V
Activation time: = 1/2 cycle
Deactivation time: = 1/2 cycle
Potential drop at rated current :
= < 1,2Vrms
Power factor = 1
Control inputs
Max. input: 10mA @32V
Max. reverse voltage: 36Vdc
GTS –T10/T20 (TRIAC version)
Control voltage: 5...32Vdc
Activation voltage: > 4,2Vdc
Deactivation voltage:< 2Vdc
GTS 15/120A (SCR version)
Control voltage: 6...32Vdc
Activation voltage: > 5,1Vdc
Deactivation voltage:< 3Vdc
Main features
• Input control from logic signal
• Switching at voltage zero crossing.
• Versions with TRIAC and with double
• LED power on indicator
• MOV protections (varistor)
• Fastening to DIN bar (standard);
O
GTS –T10 (TRIAC version)
Rated current: 10 A@40°C in
continuous service
Non-repetitive overcurrent
t= 20 ms: 30A
I2t for blowout: 72A2s
dV/dt critical with output deactivated:
500V/µs
GTS –T20 (TRIAC version)
Rated current: 20 A@40°C in
continuous service
Non-repetitive overcurrent t=20 ms: 50A
I2t for blowout: 315A2s
dV/dt critical with output deactivated:
500V/µs
GTS 15 (SCR version)
Rated current:15 A@40°C in
continuous service
Non-repetitive overcurrent
t=20 ms: 400A
I2t for blowout: 800A2s
dV/dt critical with output deactivated:
1000V/µs
GTS 25 (SCR version)
Rated current: 25 A@40°C in
continuous service
Non-repetitive overcurrent
t=20 ms: 400A
10
SCR in antiparallel.