Tandberg SLR Installation and User's Guide
Cleaning Procedure
Load the cleaning cartridge into the SLR tape drive.
1)
2) The cleaning process will begin automatically. This is
indicated by the front LEDs on the product as follows:
Tandberg SLR2 ® SLR5
· Flashing GREEN front panel LED.
3) Wait for all LED activity to finish and manually eject the
data cartridge from the tape drive (around 30 seconds).
Tandberg SLR7 ® SLR140
· Leftmost LED OFF, center GREEN LED flashing,
rightmost LED steady AMBER.
3) The cartridge will be ejected when cleaning has
completed (around 3 minutes).
Cleaning Cartridge replacement
The SLR cleaning cartridge has to be replaced when:
Tandberg SLR2 ® SLR5
· Steady GREEN front panel LED (for SLR2, SLR3,
SLR4, and SLR4DC).
· Steady AMBER front panel LED (for SLR5).
Tandberg SLR24, SLR7, SLR40, SLR50, SLR60,
SLR75, SLR100 and SLR140
· No LED activity and tape is automatically ejected.
Tandberg Data
25