Careful handling and use of battery devices
•
Charge the batteries only in chargers that are
recommended by the manufacturer. Risk of fire
if a charger that is suitable for a specific type of
battery is used with other batteries.
•
In the power tools, use only the batteries de-
signed for the purpose. The use of other batter-
ies may result in injuries and risk of fire.
•
Keep the unused battery away from paper
clips, coins, keys, nails, screws and other small
metal objects, which could cause bridging of
the contacts. A short circuit between the battery
contacts may cause burns or fire.
If used incorrectly, liquid may leak from the
•
battery. Avoid contact with this. In the event of
accidental contact, rinse off with water. If the
liquid gets into eyes, seek medical assistance.
Leaking battery fluid may cause skin irritations
or burns.
•
Ensure that the device is switched off before in-
serting the battery. Inserting a battery into a power
tool that is switched on may result in accidents.
•
Recharge the batteries indoors only because
the battery charger is designed for indoor use
only. Risk of electric shock.
•
To reduce the electric shock hazard, unplug the
battery charger from the mains before cleaning
the charger.
•
Do not subject the battery to strong sunlight
over long periods and do not leave it on a heat-
er. Heat damages the battery and there is a risk of
explosion.
•
Allow a hot battery to cool before charging.
•
Do not open up the battery and avoid mechan-
ical damage to the battery. Risk of short circuit
and fumes may be emitted that irritate the respira-
tory tract. Ensure fresh air and seek medical assis-
tance in the event of discomfort.
•
Do not use non-rechargeable batteries. This
could damage the appliance.
Warning! This electric tool generates an electromag-
netic field during operation. This field can impair ac-
tive or passive medical implants under certain condi-
tions. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical
implants consult with their physician and the manu-
facturer of the medical implant prior to operating the
electric tool.
7. Residual risks
The machine has been built according to the state of
the art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
20 | GB
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the „safety in-
structions" and the „Proper use" are observed
along with the whole of the operating instructions.
• Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet. Use the tool that is recommend-
ed in this manual.. This ensures that your machine
performs optimally.
• Hands may never enter the processing zone when
the machine is in operation.
8. Technical data
Cordless drill:
Nominal voltage:
Idle-running speed:
1st gear:
Idle-running speed:
2nd gear:
Punching power:
Drill chuck
clamping range:
Max. torque:
Weight:
Subject to technical changes!
Noise and vibration
m Warning: Noise at the workplace can exceed 85
dB (A). In this case, noise protection measures are
necessary for the user (wear hearing protection!).
Noise output in dB
Sound power level L
WA
3744)
Sound pressure level L
pA
11201)
Uncertainty K
wa/pA
Vibration value
Vibration a
h
Uncertainty K
h
9. Unpacking
• Open the packaging and remove the device carefully.
• Remove the packaging material as well as the
packaging and transport bracing (if available).
• Check that the delivery is complete.
• Check the device and accessory parts for transport
damage. Inform the transport agent immediately of
any faults. Later complaints cannot be considered.
• If possible, store the packaging until the warranty
period has expired.
20 V
max. 0 - 450 min
-1
max. 0 - 1600 min
-1
0 - 19200 bpm
max. 13 mm
45N.m
1,1 kg
72,18 dB(A) (EN ISO
83,14dB(A)
(EN
ISO
3 dB(A)
2,06 m/s²
1,5 m/s²