Lcd Display; Waste Disposal - Beninca CP.BISON 35 OTI L Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
Some messages that are displayed in the event of malfunctions are shown hereunder:
Error, self-calibration
err
Error, Inverter/Cover/Safety
Err1
Error, photocells (Autotest)
Err2
Error, encoder
Err3
Error, sensitive edge
Err4
Error, phototest
Err5
Error, inverter communication
Ecom
Triggering of the amperometric sensor
amp
F 00
Inverter, error/alarm
F 15
The LCD display can be turned by 180°.
- Cut off mains power supply
- Press PGM
- While keeping PGM pressed, reset the mains power supply
- Keep PGM pressed (around 5 sec) until the software version appears, turned by 180°.
Normally proceed with programming.
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One
segment of the display is linked to each input. In the event of failure it switches on according to the following scheme.
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal and
the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a specialised
company.
ERROR mESAGES
If the error occurs during self-learning, check the PP/STOP/PHC/
PHO/PED/BAR inputs or whether frictions occur during the door leaf
stoke.
It occurs in the following cases:
- the SAFETY contact is open.
- the COVER contact is open.
- The inverter is faulty. Contact the technical assistance centre.
Check that photocells are correctly operating.
Check connections to the encoder.
Check connections to sensitive edge
Check that photocells connections (Fig.3)
Check connections to 485 serial between control unit and inverter
An obstacle or a point of friction has caused the triggering of the am-
perometric sensor. Remove the obstacle or check the door stroke.
Take note of the error number and contact the technical assistance

LCD DISPLAY

DIAGNOSTICS
SWO
SWC
PHO3
PHO4
P.P.
PED
OPEN
PHO1
PHO2
STOP
DAS