Remplacement De La Valve D'arrêt - aquabrass TREVI Guide D'installation

Masquer les pouces Voir aussi pour TREVI:
Table des Matières

Publicité

Servicing the shut-off valve
Remplacement de la valve d'arrêt
- Shut off your main water supply. Release
the remaining water pressure by opening
the shut-off valve.
- Remove all handle components and the
trim (1 to 5) (Fig.1).
- To service the shut-off valve (6), use a
17mm socket to remove it.
- To clean the shut-off valve cartridge,
soak it in a vinegar and water solution
to remove lime build-up. If replacement is
neccessary, insert the new shut-off valve
and tighten.
- To reinstall components, just follow the
above steps in reverse. Use double-sided
mounting tape (not included) to reapply
the plate to the finished wall (make sure all
sides are sealed).
- Fermer l'alimentation d'eau principale.
Décharger la pression de l'eau en ouvrant
la valve d'arrêt.
- Démonter toutes les composantes de la
poignée et la plaque décorative (1 à 5)
(Fig.1).
- Pour retirer la valve d'arrêt (6), utiliser une
clé à cliquet avec une douille de 17mm.
- Procéder au nettoyage de la valve
d'arrêt en la plongeant dans un mélange
de l'eau et de vinaigre. Si nécessaire,
introduire une nouvelle valve et la serrer.
- Remonter les composantes en inversant
les étapes ci-dessus. Utiliser un ruban de
montage adhésif double-face (non inclus)
pour recoller la plaque décoravtive au
mur de finition (s'assurer que tous les côtés
soient étanches).
Maintenance / Entretien
6
5
52
#N1006
4
2
3
1
Fig.1
aquabrass.com

Publicité

Table des Matières
loading