Servicing the cartridges
Remplacement des cartouches
- Shut off your main water supply. Release
the remaining water pressure by opening
the diverter (N1062) or shut-off (N1004)
valve.
- Remove all handle components and the
trim (1 to 7) (Fig.6).
- To service the thermo cartridge (11),
remove the components (8 to 10) and pull
the cartridge out .
- To service the diverter or shut-off cartridge
(15), remove the components (13 & 14) and
pull the cartridge out.
- To clean the cartridges, soak them in a
vinegar and water solution to remove lime
build-up. If replacement is required, insert
the new cartridge and tighten.
- To reinstall components, just follow the
above steps in reverse. Use double-sided
mounting tape (not included) to reapply
the plate to the finished wall (make sure all
sides are sealed).
- Fermer l'alimentation d'eau principale.
Décharger la pression de l'eau en ouvrant
une valve du déviateur (N1062) ou la
valve d'arrêt (N1004)
- Démonter toutes les composantes des
poignées et la plaque décorative (1 à 7)
(Fig.6).
- Pour retirer la cartouche thermostatique
(11), démonter les componsantes (8 à 10).
- Pour retirer la cartouche du déviateur
ou de la valve d'arrêt (15), démonter les
composantes (13 & 14).
- Procéder au nettoyage des cartouches
en les plongeant dans un mélange de
l'eau et vinaigre. Si nécessaire, introduire
une nouvelle cartouche.
- Remonter les composantes en inversant
les étapes ci-dessus. Utiliser un ruban de
montage adhésif double-face (non inclus)
pour recoller la plaque décoravtive au
mur de finition (s'assurer que tous les côtés
soient étanches).
aquabrass.com
Maintenance / Entretien
#N1004, #N1062
For N1004 / pour N1004
15
14
11
10
8
9
For N1062 / pour N1062
15
14
11
10
8
9
49
13
6
7
4
3
13
5
6
7
4
2
3
5
1
2
Fig.6
1
Fig.6

Publicité

Table des Matières
loading

Table des Matières