Craftsman CMXEOCG322 Manuel Du Propriétaire page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FASTEN THE DOOR BRACKET (CONTINUED)
ONE-PIECE DOORS
Please read and comply with the warnings and reinforcement instructions on the
previous page. They apply to one-piece doors also.
• Center the door bracket on the top of the door, in line with the header
bracket as shown. Mark either the left and right, or the top and bottom
holes.
• Metal Doors: Drill 3/16" pilot holes and fasten the bracket with the 1/4"-
14x5/8" self-threading screws provided.
• Wood Doors: Drill 5/16" holes and use 5/16"x2" carriage bolts, lock
washers and nuts (not provided) or 5/16"x1-1/2" lag screws (not provided)
depending on your installation needs.
NOTE: The door bracket may be installed on the top edge of the door if required for
your installation. (Refer to the dotted line optional placement drawing.)
Header Wall
Header
Bracket
Door
Bracket
Optional
Placement
of Door
Bracket
Vertical
Centerline of
Garage Door
HARDWARE SHOWN
ACTUAL SIZE
Self-Threading Screw
1/4"-14x5/8"
2x4
Finished Ceiling
Support
HORIZONTAL AND VERTICAL
REINFORCEMENT IS NEEDED
FOR LIGHTWEIGHT GARAGE
DOORS (FIBERGLASS, ALUMINUM,
STEEL, DOORS WITH GLASS
PANEL, ETC.). (NOT PROVIDED)
For a door with no exposed framing,
or for the optional installation, use
lag screws 5/16"x1-1/2" (Not Provided)
to fasten door bracket.
Door
Bracket
Nut
5/16"-18
Door
Bracket
20
Self-Threading
Screw
1/4"-14x5/8"
Top of Door
(Inside Garage)
Top Edge
of Door
Optional
Placement
METAL DOOR
Lock
Washer
5/16"
Top of Door
(Inside Garage)
Top Edge
of Door
Optional
Placement
Carriage Bolt
5/16"x2"
(Not Provided)
WOOD DOOR

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Cmxeocg572Cmxeocg772Cmxeocg982

Table des Matières