AIR SYSTEMS
Calculating Compressor Size
Use the air consumption chart in the Tool
Schematic for each tool when calculating
the operating requirements for the tools.
Paslode tools are designed to operate ef-
fciently between 80 and 120 psi and should
never be operated at pressure greater than
120 psi.
The air consumption chart will help you find
the correct compressor size for your appli-
cation that will quickly replenish tool air pres-
sure. To use the chart you will need to know
how many tools will be used and approxi-
mately how many fasteners will be driven
each minute by each tool onthe line.
Using the equation:
Number of tools X average fasteners/minute/
tool X 1.2 (safety factor) X air consumption
(scfm) @ pressure* (psi) = scfm required.
We can use the following example:
10 tools X 30 fasteners/minute/tool X 1.2 X
0.051scfm* (@100psi) = 18.36 scfm.
*This number is found in the Air Consumption
Chart
In this example, using the air consumption
chart we find that a compressor providing at
least 19 scfm of air is required. Because in
compressors approximately 1 hp is required to
produce 4 scfm, a compressor of at least 5 hp
is required.
- Continued
Calculated Required Piping
For example, given a 20 hp electric compressor
supplying approximately 80 cfm of air at 120 psi
and a main supply pipe length of 350 feet, we see
by the table the minimum main pipe inside diam-
eter required for this application is 1-1/4 inch.
VOLUME
OF AIR
50-200
290-500
(CFM)
NOMINAL PIPE DIAMETER (IN.)
30-60
1
1
60-100
1
100-200
200-500
2
500-1000
3
Pneumatic System Maintenance
- Be certain that:
• Pneumatic fittings are tight and do not leak.
and ensure that automatic draining systems are
operating correctly.
• Air lines are cleared to prevent freezing,
especially in winter.
• Lubricator operation is checked regularly and
ensure it has an adequate supply of lubricant.
(Paslode Part No. 403720)
• Only regulated air is being used and that each
regulator is operating properly.
8
LENGTH OF RUN (FT.)
500-1000
1000-2500
2500-5000
2
2
3
4
2