Troubleshooting - Sentiotec just sauna fin JUST-105D-FI Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation instructions, only for experts

13. Troubleshooting

Error messages
The sauna control unit is equipped with diagnostic software which monitors
system statuses at start-up and during operation. As soon as the diagnostic
software identifies an error, the sauna control unit switches the sauna heater off.
Errors are indicated by a recurring warning tone emitted by the power unit and
by the flashing lights on the LED wheel
the error number is displayed with the help of the power level display
number of LEDs on it which are flashing indicates the error number. The following
table describes the possible errors and their causes. If necessary, tell the error
number to your customer service specialist.
Switch the sauna control unit off on the power unit using the ON/OFF switch A
and rectify the error before switching the sauna control unit on again.
Error
01
Safety shut-off
02
Excess temperature
fuse
03
Communication error
04
Heater sensor error
05
Foil sensor error
06
Bench sensor error
08
Foil sensor
excess temperature
WORLD OF WELLNESS
Description
on the operating unit. Furthermore,
c
Cause / rectification
An object has been placed on the sauna
heater. Remove any objects before start-
ing up the sauna heater again.
The maximum temperature of 139 °C
has been exceeded above the heater.
No power unit has been connected,
or the contact is poor.
Defective heater sensor, poor contact,
or short circuit.
Defective foil sensor, poor contact,
or short circuit.
Defective bench sensor, poor contact,
or short circuit.
The maximum foil temperature of 100 °C
was exceeded.
p. 42/44