Static Frequency Tolerance: There are 6 settings (1,2,4,6,8,10%), and the default setting is +/- 6%.
Function description: The settings may be adjusted to the quality of the electricity in use.
e.
Slew Rate: Also called Dynamic Frequency Tolerance. There are 5 different settings
(0.25,0.5,1,2,4 Hz/Sec). The default value is 4Hz/sec.
Function description: "Slew Rate" indicates the tolerance of a device in accepting frequency
variances. The lower "Slew Rate" results in less tolerance but better protection for the connected
loads.
f.
Low Battery Shutdown Voltage: This function adjusts the EPS shutdown point according to the
battery voltage. The default setting is 10.8V (with load).
g.
Mode Select: The standard mode (setting: 2) and the robust mode (setting: 1) are provided to
select. Using the generators is suggested to select the robust mode (setting: 1), and using the
computers is suggested to select the standard mode (setting: 2). The system default setting is
standard mode (setting: 2).
The settable items are sorted by unit as in the following table:
Delay Time
Charging Current
Nominal Output Voltage
Static Frequency Tolerance
Slew Rate
Low Battery Shutdown
Voltage
Mode Select
Step 3: Press and hold the toggle for 4 seconds. When the icons blink, the value of each item can be
changed by slightly pressing the toggle.
Step 4: To save the value and return to general mode, press and hold the toggle for 4 seconds.
Note: If the machine is left idle for over 30 seconds during setup, it will turn off the backlight and
return to general mode automatically.
Note: If user wants to return to general mode without saving changes, there are two methods:
1. Wait for the backlight to turn off
2. Press and hold the "Display" toggle for 10 seconds
1.
Overheat Protection: The EPS output will be interrupted. After 30 seconds, the machine shuts
down and the LCD display output voltage is zero.
2.
Over-Load Protection The EPS output will be interrupted. After 30 seconds, the machine shuts
down and Over Load Icon lights on the LCD display.
3.
Battery Missing You should hear a long beep and Battery Indicator flashes
4.
Low Battery Protection: The EPS output will be interrupted. After 30 seconds, the machine shuts
down and the LCD display output voltage is zero.
5.
The following table shows each corresponding warning message on the LCD display and the
alarm reacts during the machine shut down
Items
FAULT WARNING DISPLAY AND ALARM
Unit
Min
ON BAT
%
ON BAT
V
NORMAL MODE
%
NORMAL MODE
%
None
V
ON BAT
None
None
Icon Lit