SILENT MODE Icon: This icon appearing indicates that the buzzer does not beep in the silent
mode until the low battery capacity.
6.
OVER LOAD Icon: This icon appearing and an alarm activated indicate that the overload
condition. To relieve the overload, unplug your equipment from the EPS outlets until the icon
disappears and the alarm stops being activated.
7.
LOAD CAPACITY: Load CAPACITY is also shown on the bar chart; equal 25% load capacity for
each segment.
BATTERY VOLTAGE: BATT. VOLTAGE indicates the voltage of battery.
8.
EPS STATUS INQUIRY AND FUNCTIONS SETUP
GENERAL MODE
a.
Press the "Display" button to check the status of the EPS
b.
Press and hold the Display toggle for 4 seconds.
If the machine is in the Battery Mode, it enters the silent mode. Press again for 4 seconds and it
will return to normal (buzzer) mode.
If the machine is in the Line Mode, it proceeds to Self Test.
c.
If the Display toggle remains untouched for over 30 seconds, the LCD backlight will turn off
automatically.
SET-UP MODE
Step 1: Hold the Display toggle for 10 seconds to enter the EPS set-up Mode. LCD icon 1, 2 lights
indicate Set-Up Mode.
Step 2: By pressing the Display toggle, users can switch between setup functions. User configurable
functions are as follows:
a.
Delay Time: The time delay between switching from Battery Mode to Line Mode. There are 9
different settings. The default setting is 0.0 minute.
Function description: The machine will switch from Battery Mode to Line Mode after the AC
power transmission reaches stability within the preset delay time.
b.
Charging Current: The function adjusts the battery charging current according to the capacity of
the connected batteries. It can be configured for 25, 50, 75, and 100%. The default setting is 75%.
100% indicates that charging current is about 10Amps.
c.
Nominal Output Voltage: Configures the correct electricity/voltage supplied in the area/country
where the EPS will be used. 220V and 230V may be selected. The system default setting is 230 V.
Function description: AVR Dynamic Voltage Compensation works automatically based on the
system voltage settings.
Items
Input Voltage
Output Voltage
Load Capacity
Battery Voltage