Notice: When the pump is used with an external control, the
connection to the external control has to be interrupted or the
external control has to be disconnected from the mains voltage
when programming the performance level and the priming time!
Notice: During the suction phase it is not possible to change the
performance level.
EN 16
Operation:
Press button
performance level.
If the pump starts from a standstill, it starts up in
priming mode and subsequently with the selected
performance level.
As long as the pump is in the priming phase, the LED
of the selected performance range flashes.
During running operation the pump is started up
directly to the performance level, without priming time.
The motor is stopped by pressing the button
"Power" LED flashes and the display shows "OFF".
Setting the performance level:
Press the button of the performance level which is to
be changed and then keep the
at least 3 seconds until the performance displayed in
the display begins to flash. Now the performance can
be changed with the buttons
performance confirm with
original performance press the
Setting the priming parameters:
The motor has to be stopped (
programme the priming time. Then press the
again for at least 3 seconds until the performance
displayed in the display begins to flash. Now the
performance with which the motor is to start up during
the priming time can be set. The performance can be
changed with the buttons
After the priming capacity has been set, the length of
the priming time can be specified. The priming time
can be set between 0 (=Off) and 10 minutes.
or
to select the preset
button pressed for
. To save the
. To cancel and retain the
button.
button) to
and saved with
. The
button
.