When it's not the case, there might be energetic recovery systems to the general
power supply. Through this staff of the power supply may be shocked from the vol-
tage of the generator, for instance at maintenance works at energetic blackouts.
When the power supply is turned on again, there might be an explosion or fire of the
generator.
5.2

Connecting devices

Before connecting a device on the AC socket you must control the perfect condi-
tion of the device.
When you recognise that a connected device acts unusual you must stop the ge-
nerator and disconnect the device. Control whether the device is damaged or if
the generator was overchallenged by the device.
ATTENTION: A short exceed of the normed power capacity of the generator is possi-
ble but if this happens oftener the life time of the generator will be shortened.
In exceptions the generator can be charged with the maximum power for max. 30
minutes.
The following list gives you a view about the differences of the electricity requirement
of some devices between start and continuous operation.
Verbrauchsart
Electrical equip-
ment
Light
Devices with
engines
Please consider: Some devices, for instance cooling devices need up to 5 times more starting
current than current during the operation.
5.3
AC Operation
Connect the devices to the AC socket. The most devices need more energy (VA) for
starting than declared. A device with a normed power requirement of 1500 VA might
charge your generator up to its maximum for a short time.
.
Z.I.P.P.E.R Maschinen Austria
Expenditure
Instance type of de-
of watt
vice
Start
During
opera-
tion
X1
X1
X1,5
X1
X
X2
3~5
www.Zipper-maschinen.at
Instance
device
Start
100VA
80VA
450-
750VA
During
operation
100VA
60VA
300VA