Troubleshooting; Change Over To Gas Mode - Truma AquaGo Serie Mode D'emploi

Trousse antigel électrique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• During operation, the yellow status LED 3
(see Fig. 8 - LED 3) is lit.

Troubleshooting

Problem
The Truma AquaGo™
instant water heater
does not start in gas
mode.
Remove the plug from the flue duct and clamp
it beneath the holder (see Figure 9).
The yellow status
LED 3 is not lit.
Check the connection on connector X1. You
may have to disconnect it and connect it again.
The yellow status
LED 3 is flashing.
See "Description of the yellow status LED 3"
in operating modes (control panel) in the op-
erating instructions for the Truma AquaGo™
instant water heater.
Potential cause
– The plug is blocking
the flue duct.
– The heating cartridge
is not attached or is
defective.
– There is a
malfunction.
If none of the measures in the troubleshooting
chart proves successful, please contact your
dealer, the Truma Service Center on 1-855-558-
7862 or one of our authorized service partners.

Change over to gas mode

If you change the Truma AquaGo™ instant
water heater back to gas mode, the heat-
ing cartridge can remain in the Truma AquaGo™
instant water heater.
1. Remove the access door.
2. Switch OFF the Truma AquaGo™ instant
water heater at the POWER switch and at the
control panel (set Operating mode to OFF).
3. Remove the plug from the flue duct and
clamp it beneath the holder (see Figure 9).
13

Publicité

Table des Matières
loading

Table des Matières