Table 5 : Technical Specifications, Olb53F / Olf105 & Nolf105 - Dettson OLR105A12D Mode D'emploi

Fournaise à mazout à flux ascendant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table 5 :
RATING AND PERFORMANCE
Firing rate (USGPH)
Input (BTU/h)
Heating capacity, chimney installation (BTU/h)
Heating capacity, side-wall installation (BTU/h)
Minimum - maximum temperature rise
Flue draft, (Chimney), (Side-wall)
Overfire pressure (chimney), (Side-wall)
BECKETT BURNER, CHIMNEY INSTALLATION
Burner tube insertion lenght (inches)
Low firing rate baffle
Static disc, model
Nozzle (Delavan)***
Pump pressure (PSIG)*
Combustion air adjustment ( band/shutter )
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER, CHIMNEY INSTALLATION
Burner tube insertion lenght (inches)
Nozzle (Delavan)***
Pump pressure (PSIG)*
Combustion air adjustment (turbulator / damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
BECKETT BURNER, SIDE-WALL INSTALLATION
Burner tube insertion lenght (inches)
Nozzle (Delavan)****
Pump pressure (PSIG)*
Combustion air adjustment (screw / dial) or (dial only)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER, SIDE-WALL INSTALLATION
Burner tube insertion lenght (inches)
Nozzle (Delavan)***
Pump pressure (PSIG)*
Combustion air adjustment (turbulator / damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Operating voltage range (Volts)
Electrical load (Amps)
Minimum ampacity for wiring sizing
Max. fuse size (Amps)
Control transformer
Ext. control power available, cooling and accessories
BLOWER DATA
Blower speed at 0.50" W.C. static pressure
Blower speed at 0.25" W.C. static pressure
Maximum cooling, speed
Maximum cooling, tons @ 0.50" W.C.
Motor (HP) / number of speeds
Blower wheel size (in.)
Filter quantity and size (in.)
‡ = NON-AVAILABLE IN UNITED STATES
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature is under 400°F.
- Adjust the total flue gas temperature between 400°F and 575°F (330°F and 505°F net approximately)
** AFUE values established after minimum 20 hours of operation.
*** Default installed NOZZLE in bold characters.
Technical Specifications, OLB53F / OLF105 & NOLF105
Model :
(N)OLB53F / (N)OLF105
0.50
70 000
88 200
59 200
73 000
59 400
73 200
11 - 24°C (52 - 75°F)
(-0.035" to -0.06") (+0.04" to +0.16")
(0.00" to +0.035") (+0.10" to +0.25")
Yes
2 3/4 #3383
2 3/4 #3383
0.50 - 70A
0.50 - 70A
100
0 / 4.5
85.2
85.2
0.40 - 60A
0.50 - 60A
156
0 / 2
85.9
86.0
0.50 - 60W
0.50 - 60W
130
3 / 1.5
84.2
83.1
40-BF3 with AL1009 post purge control
0.50 - 60W
0.50 - 60W
135
0 / 3
84.8
84.7
LOW
MED-HI
LOW
MED-HI
LOW
MED-LO
1.5
18
0.63
0.75
105 000
87 800
88 200
AFG with F0 head
5 1/8''
Yes
No
2 3/4 #3383
0.60 - 70B
156
156
0 / 8
0 / 7.5
83.4
83.5
83.4
79.6 ‡
40-F3
5 3/16''
0.60 - 60A
156
156
0 / 3
0 / 4
83.5
82.2
83.4
82.3 ‡
AFII-85
4 15/16''
0.60 - 60W
140
160
3 / 3
3 / 4.5
83.0
81.9
81.5 ‡
78.7 ‡
5 3/16''
0.60 - 60W
140
0 / 6
83.0
83.2
115 - 60 - 1
104 - 132
12.2
13.7
15
40 VA
30 VA
HIGH
HIGH
MED-HI
2
2.5
1/3 HP / 4 speeds
10 X 10
(1) 20 X 20
0.72
100 800
84 200
155
0 / 7.5
82.0
82.0 ‡
HIGH
HIGH
HIGH
3