112 Series, multi-position models
RATING AND PERFORMANCE
Firing rate (USG PH)*
Input (BTU/h)*
Maximum Heating capacity, (BTU/h)*
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pres sure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pres sure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner t ube insertion length (inches)
Head type
Nozzle (Delavan)
Pump pressure (PSIG)*
Head/ Air setting
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner t ube insertion length (inches)
Nozzle (Delavan)
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-BF5 (Direct vent DV)
Burner t ube insertion length (inches)
Nozzle (Delavan)
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps )
Max. fuse size (Amps)
Control transformer (VA)
External control power available
Heating (VA)
BLOWER DATA
Heating blower speed at 0. 25" W.C. SP
Heating blower speed at 0. 50" W.C. SP
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL I NFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x dept h)
Filter size
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons ) at 0.5" W.C. SP
* INPUT & OUTPUT ADJUSTMENT:
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature is under 400˚F
- Adjust the total flue gas temperature between 400˚ and 575˚F (330˚ and 505˚ F net approx.)
** AFUE value established after minimum 20 hours of operation.

Table 6: Technical Specifications

Cooling (VA)
UNITS 1/2 HP 4-SPEED MOTOR
0.68
0.80
95 200
112 000
81 000
94 000
55 - 75 Degr. F
-0.06 to -0.025
-0.035 to +0. 025
+0.03 to +0.15
+0.05 to +0.17
NX56LQ
1 3/4''
6 - Slot LQ head
0.60 - 60A
0.70 - 60A
130
130
1.5
2.5
85.5 ‡
85. 0 ‡
85.2 ‡
85. 0 ‡
F3 WITH AIR INLET DAMPER
2 3/4''
0.60 - 70A
0.70 - 70A
130
130
1 / 2.6
2 / 3.1
85.5 ‡
85. 0 ‡
85.2 ‡
85. 0 ‡
BF5
2 3/4''
0.60 - 70A
0.70 - 70A
130
130
0 / 2.75
0 / 3.25
85.5 ‡
85. 0 ‡
85.2 ‡
85. 0 ‡
115 - 60 - 1
12.6
15.2
20
40
40
30
MED-LO W
MED-HIGH
MED-LO W
MED-HIGH
1/2 HP / 4 speeds
10'' x 10'' (tight housing)
21 3/4'' x 25 3/4'' x 41 1/2''
17 3/4'' x 18 3/4''
23'' x 19''
24'' x 20'' x 1"
153 Lbs / 70 Kg
3. 5
14
UNITS WITH 1/2 HP ECM MOTOR
0.68
0.80
95 200
112 000
81 000
94 000
60 - 72 Degr. F
-0.06 to -0.025
-0.035 to +0.025
+0.03 to +0.15
+0.05 to +0.17
NX56LQ
1 3/4''
6 - Slot LQ head
0.60 - 60A
0. 70 - 60A
130
130
1.5
2.5
85.5 ‡
85.0 ‡
85.2 ‡
85.0 ‡
F3 WITH AIR INLET DAMPER
2 3/4''
0.60 - 70A
0. 70 - 70A
130
130
1 / 2.6
2 / 3.1
85.5 ‡
85.0 ‡
85.2 ‡
85.0 ‡
BF5
2 3/4''
0.60 - 70A
0. 70 - 70A
130
130
0 / 2.75
0 / 3.25
85.5 ‡
85.0 ‡
85.2 ‡
85.0 ‡
115 - 60 - 1
10.3
12.2
15
40
40
30
See the ECM air flow t able
1/2 HP / ECM
10'' x 10'' (tight housing)
21 3/4'' x 25 3/4'' x 41 1/2''
17 3/4'' x 18 3/4''
23'' x 19''
24'' x 20'' x 1"
153 Lbs / 70 Kg
3.5
‡ =