REGULAR MAINTENANCE
Please read the "Engine Instructions Manual" carefully for
Engine Maintenance.
The best guarantee for long working life and constant readiness
of the walk-behind duplex roller is correct and regular
maintenance.
INITIAL BREAK-IN MAINTENANCE
Any new equipment requires an initial modification of the
maintenance schedule to properly break-in the various systems
and component units. Perform this one time initial break-in
maintenance after 50 to 100 hours of operation IN ADDITION
TO the 10 hour, 50 hour and 100 hour maintenance tasks which
are described on the following pages. After this initial phase, the
regular intervals should be followed.
Engine Oil
Drain the engine oil after the first 20 hours of operation. Fill with
the correct amount of the recommended oil. Check the oil level
with the oil filler cap/dip stick. See "500 HOUR OR SEMI-
ANNUAL ROUTINE MAINTENANCE" to change the engine oil.
Table 1 Inspection Intervals – DX-500E
No
Inspection Item
Looseness of bolts and nuts
1
Damage, oil leakage
2
V-belt
3
Eccentric Shaft Case Oil
4
Hydraulic Oil Tank
5
Oil Filter
6
Table 2 Inspection Intervals – DX-700E
No
Inspection Item
Looseness of bolts and nuts
1
Damage, oil leakage
2
V-belt
3
Eccentric Shaft Case Oil
4
Hydraulic Oil Tank
5
Oil Filter
6
Hot oil and/or components can burn.
Oil must be at normal operating temperature when
draining.
Avoid contact with hot oil or components.
Eccentric Shaft Case Oil
Drain the eccentric shaft case oil after the first 50 hours of
operation. Remove the drain plug, and the fill plug. Drain out the
oil and fill with the correct amount of the recommended oil.
Check the oil level before each use of the machine.
Check each part of lose or broken bolts and nuts
Tighten loose Bolts and Nuts, if any. Check each part for fuel oil
leak. Replace broken or damaged parts, if any, with new ones.
Daily
Every 24 hrs
Check-up
Check-up
Check-up (Reserve)
Replacing (Initial)
Daily
Every 24 hrs
Check-up
Check-up
Check-up (Reserve)
Replacing (Initial)
10-EN
WARNING
Every 100 hrs
Check-up
Replacing
Check-up
Replacing
Check-up
Replacing
Every 100 hrs
Check-up
Replacing
Check-up
Replenishing
DX-500E/DX-700E Walk Behind Duplex Rollers
Operation & Maintenance Manual
Every 500 hrs
Replacing
Every 500 hrs
Replacing
Replacing