AIR SUPPLY

Tools of this class operate
on a wide range of air
pressures. We recommend
that air pressure measures
90 PSI at the air inlet while
in use. Low pressure (less
than 90 psig/6. bar) reduces
the speed and performance
of all air tools. High pressure
(over 115 psig/8.0 bar)
ex­ceeds the rated capacity of
the tool, which will shorten
tool life through faster wear
and could cause injury.
Always use clean, dry air.
Dust, corrosive fumes, and/
or water in the air line will

LUBRICATION

Lubricate the air motor daily
with NAPA air tool oil. If no
air line oiler is used, run
1/ oz. of oil through the
please revieW all Warning insTrucTions prior To operaTion. save This Manual for fuTure reference.
6-1074
cause damage to the tool.
Drain the air tank daily.
Clean the air inlet filter
screen at least once per
week.
The air inlet used for
connecting the air supply has
Forward/Reverse
Lever
tool. The oil can be sq­uirted
into the tool air inlet or into
the hose at the nearest
connection to the air supply,


standard /8" NPT American
Thread. Line pressure should
be increased to compensate
for unusually long air hoses
(over 5 feet). Minimum
hose diameter should be
1/" I.D. Fittings should have
the same inside dimensions
and should be tightly
secured.
Air Inlet
then run the tool. Overfilling
will cause a reduction in the
power of the tool.