WARNING: BEFORE MAKING ANY ADJUSTMENTS, MAKE SURE THE THROWING
ARM IS IN THE UNCOCKED POSITION, THE ON/OFF/SAFE RELEASE SWITCH IS IN
THE "OFF" POSITION, AND THE BATTERY IS DISCONNECTED FROM THE TRAP.
UNINTENTIONAL FIRING OF THE TRAP CAN CAUSE INJURY OR DEATH FROM
BEING STRUCK BY THE THROWING ARM.
WARNING: DO NOT TRANSPORT OR STORE TRAP WITH MAINSPRING INSTALLED
OR BATTERY ATTACHED. UNINTENTIONAL FIRING OF THE TRAP CAN CAUSE
SERIOUS INJURY OR DEATH FROM BEING STRUCK BY THE THROWING ARM.
WARNING: NEVER REMOVE THROWING ARM PATH INDICATOR UNLESS
MAINSPRING HAS BEEN REMOVED FIRST. NEVER OPERATE TRAP WITHOUT
THROWING ARM PATH INDICATOR IN PLACE. SERIOUS INJURY OR DEATH CAN
RESULT.
WARNING: DO NOT MANUALLY FORCE THE THROWING ARM THROUGH THE
UNCOCKED POSITION AS THE MAIN SPRING WILL TAKE OVER AND FIRE THE
TRAP, POTENTIALLY CAUSING SERIOUS INJURY OR DEATH.
1. Make sure the throwing arm is in the uncocked position, the on/off/safe release switch
is in the "off" position, and the battery is disconnected from the trap.
2. Carefully release spring tension by loosening the Handnut (S4).
3. Remove the Mainspring (S1).
4. To prevent lost parts, reattach Handnut (S4) and Bushing (S3) to Mainspring Bolt (S2) for
transportation.
5. Once the Mainspring (S1) is removed, manually rotate the throwing arm to the 6 o'clock
position where it will be protected and is as compact as possible.
6. Remove magazine assembly by sliding the magazine rods off the magazine studs.
7. If necessary, detach Throwing Arm Path Tubing (A3) from both Throwing Arm Path
Indicator Tube Studs (A2) and both Throwing Arm Path Indicator Tube Supports (A1).
8. If necessary, unscrew both Throwing Arm Path Indicator Tube Supports (A1) from trap.
9. Store trap indoors away from the elements and out of children's reach.
VII. Transportation and Storage
20