BULK CHARGING TIME
Battery size (Ah)
100
225
500
TECHNICAL DATA
Model
Voltage AC
Current
Back Current Drain*
Charging Voltage
Ripple**
Charging Current
Ambient Temperature - 4°F to +122°F. Automatic reduction of power at increased
Cooling
Charge cycle
Type of batteries
Battery Capacity
Dimensions
Weight
*) Back Current Drain is what the charger uses to drain the battery if the power cord is
disconnected. The reverse current of the MULTI US 25000 is very low.
**) The ripple wave describes how many disturbances are exhibited by current and volt-
age. A rippled voltage can cause damage to other equipment connected to the battery.
The MULTI US 25000 supplies voltage and current with very low voltage rippling. This
increases the life of the battery and ensures that equipment connected to it will not be
damaged.
12 • US
60
1041
1 10–120VAC, 60Hz. Output power is reduced at
lower input voltage.
6.0A rms
< 2mA/month
Nominal: 12V or max 15.7V
<4%
25A max
ambient temperature.
Fan
MULTI US 25000 is a 8-step fully automatic charger.
A ll types of lead-acid batteries (Wet, Maintenance Free, AGM,
Ca/Ca and most GEL).
50–500Ah
9¼ x 5⅛ x 2½ inches (L x W x H)
4.2 lbs
Time to ~80% charge (h)
2
3
7
16