Télécharger Imprimer la page

Fein Slugger JCM 200 QX Mode D'emploi page 24

Publicité

Les langues disponibles

Les langues disponibles

OBJ_BUCH-0000000130-003.book Page 24 Thursday, December 15, 2016 1:40 PM
en
24
Repair and customer service.
Before mounting or replacing cutting tool or accessories, pull the power plug.
WARNING
This preventive safety measure rules out the danger of injuries through acciden-
tal starting of the power tool.
Exchangeable parts
If required, you can change the following
parts yourself:
application tools, coolant container
Drill-motor guide (figure 19).
After several hours of operation, the play in
the drill-motor guide can increase. As a con-
sequence, the drill motor can glide alongside
the drill-motor guide. In automatic machine
operation, this can lead to a malfunction of
the automatic reversing feature. In this case,
retighten all fastening screws of the drill-
motor guide correspondingly so that the drill
motor can easily be moved manually, yet does
not glide by itself.
Service.
Have maintenance carried out
WARNING
only through qualified person-
nel. Incorrectly mounted cables and compo-
nents can cause serious injuries. Have the
required service carried out only through an
authorized Slugger repair facility.
When replacing the power
CAUTION
tool's protective cable bushing
or cord between the drill stand and drill
motor is required, this must be carried out by
Slugger or by an authorized Slugger Service
Agent, in order to avoid hazardous situations.
The current spare parts list for this power
tool can be found in the Internet at
www.fein.com.
Fig.19
2,5 mm
3/32 in
Cleaning.
Prior to any cleaning or main-
WARNING
tenance, disconnect the power
tool from the power supply in order to avoid
accidents.
When using in environments
WARNING
with conductive dust in the air,
such as when cutting metals, this dust can
settle in the interior of the power tool. This
can impair the total insulation of the power
tool. Therefore, regularly blow out the interior
of the power tool from outside via the ventila-
tion openings with dry, oil-free compressed
air; always wear eye protection when doing
this. For additional protection, connect a
ground fault circuit interrupter (GFCI) on the
line side.
Fastening
screws
Drill-motor
guide

Publicité