Technical Data

Electrical data
Approximate Power
consumption per device:
Housing
Housing material:
Dimensions (W*xHxD):
* Width on top hat rail
Weight:
Assembly:
EMV:
Zugentlastung:
Environment
Degree of protection
conforming to EN 60529:
Working temperature
range:
Storage
temperature range:
For non-condensing
Conformity:
The AC-4704 meets the EN 61326-1 Standard with interference emission conforming to class A
(Industry)
Assembly:
The AC-4704 is assembled on a 35 mm rail (DIN EN 50 022).
Figure 2) Mounting the top hat rail
© Brüel & Kjaer Vibro ● 10/2017 ● C106022001 / V05
Technical alterations reserved!
1 W
PVC UL94 V0
56 mm x 90 mm x 50 mm
77 g
on 35 mm mounting
rail (DIN EN 50 022)
EN 61326-1
Ø 3,5 mm - 6,5 mm
IP20
-5 °C bis +65 °C
-30 °C bis +85 °C
1) Place the mounting device on the back of the AC-4704
interface on the top of the rail.
2) When clipping on the top hat rail the AC-4704 must be
placed at its intended terminal position as any slipping on
the top hat rail may cause damage to the housing.
3) Turn the interface downwards until the clamping is
engaged.
humidity max.
Connections
Supply voltage (U
):
IN
Sensor:
- Constant
Power supply I
:
B
- Voltage supply U
VI-6080 connection:
MTBF/MTTF
Telcordia Standard Issue 3:
(ground fixed, uncontrolled environment)
3062 years:
1420 years:
411 years
EN
Technical Data
95 %
24 VDC ±15%
8,5 mA (±10%)
U
-1 V
B
IN
RJ45 socket for a
Patchcable
(SF/UTP)
-5 °C
+25 °C
+65 °C