Jumper
The jumper connects the shield ground potential to the top hat rail (usually protective ground) and
should be inserted for a better EMC behaviour.
Figure 4)
AC-4704 with Jumper
NOTE!
Due to an alternative grounding concept if a connection of the shield ground potential with
the potential of the top hat rail is not desired, the jumper can be removed.
VI-6080 Connection
 Use a suitable network cable (Cat.6 S/FTP patch cable with PiMF or S/STP) to connect the
AC-4704 to the VI-6080 (connection via the AC-4704's RJ45 jack using the vibration input socket's
Channels 1 - 4 and Channels 5 - 8 in the VI-6080).
24 VDC Anschluss
+
+ 24 DC
0 VDC

Ordering code:

AC-4704
PCABLE-C6-YE-XXXX
© Brüel & Kjaer Vibro ● 10/2017 ● C106022001 / V05
Technical alterations reserved!
1) Power the device using the +24 VDC connectors with the necessary
external voltage.
2) Use the second +24 VDC connection socket to supply voltage to an
additional AC-4704. In this manner up to 10 interfaces AC-4704 can
be chained with supply.
3) Switch on the power supply.
Sensor interface
patch cable (Cat.6 S/FTP); yellow
length in metres xxxx =
0025 = 0,25 m
0100 = 1,00 m
0200 = 2,00 m
0500 = 5,00 m
2000 = 20,0 m
Figure 5)
AC-4704 without Jumper
0050 = 0,50 m
0150 = 1,50 m
0300 = 3,00 m
1500 = 15,0 m
3000 = 30,0 m