To install the IntelliChlor cell:
1. Using PVC glue, mount the PVC couplings to the plumbing pipe. Allow the glue to dry.
2. Mount the cell to allow access to the control panel. Install the cell onto the couplings.
Ensure the O-rings are seated properly.
3. Switch on the pump and visually inspect for leaks around the couplings.
Connecting the IC20, IC40 Cell Power Cable to the Power Center
After the cell installation is completed, connect the power cable to the Power Center:
WARNING - Switch OFF main system power to the Power Center before making any connections.
1. Be sure that AC power is switched OFF before connecting the power cord to the Power Center.
2. Align the four (4) pins of the cell power cord connector with the socket on the bottom of the Power
Center and insert the connector. Turn the round socket nut until it locks the connector in place.

Connecting the Power Supply Cable to the IC15 Cell

WARNING - Switch OFF main system power to the Power Center before making any connections.
After the IC15 cell installation is completed, connect the cell power cable to the Power Supply:
Align the four (4) pins of the cell power cord connector with the socket on the side of the Power
Supply and insert the connector. Turn the round socket nut until it locks the connector in place.
Power Supply connector
To cell assembly
IC15 Power Supply
IntelliChlor Electronic Chlorine Generator Installation and User's Guide
Connector socket nut.