Télécharger Imprimer la page

Salt Level Status Leds; Status Leds - Pentair INTELLICHLOR IC15 Installation Et Guide D'utilisation

Masquer les pouces Voir aussi pour INTELLICHLOR IC15:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 87

Salt Level Status LEDs

The IECG salt level checks the pool water daily and displays the levels as follows:
Green LED: Good salt. The pool water salt level is between 2800 ppm
and 4500, and the IECG is producing chlorine. IECG salt LED should
always be showing GREEN level for better results.
Green LED (Flashing): Salt level is above 4500 ppm. Chlorine is being
produced but the salt level is too high which increases the risk of
corrosion and deterioration of pool equipment and surfaces in and around
the pool. Pool water needs to be drained and refilled one (1) foot at a time
until the salt level is below 4500 ppm.
Red LED: Low salt. The water salt level is below 2800 ppm. The IECG
will be producing chlorine at reduced efficiency. It is highly recommended
to add salt. See (*) Note below.
Red LED: Very low salt . The water salt level has fallen below 2600 ppm.
The IECG will not produce chlorine until salt is added. The IECG is OFF.
See (*) Note below.
NOTE (*): After every salt addition, pump should be allowed to run for
at least 24 hours for proper dilution. Salinity readings should only be
taken, after the dilution period.
DO NOT take salinity readings during the dilution period, otherwise
readings WILL NOT be accurate.

Status LEDs

Cold Water: Shows the IntelliChlor Electronic Chlorine Generator power
status:
No Light: .The IECG is operating in the normal temperature
range (> 52° F)
Red: The IECG is in "Standby" mode (system off, no chlorine
production) due to a cold water condition. The IECG will resume
to normal operation mode, including accurate salinity report,
once water temperature goes above 52° F.
Cell: Shows the status of the IECG.
Green (flashing): The IECG needs to be inspected. The blades
may have calcium buildup. The IECG is not producing chlorine.
Green: IECG is good and producing chlorine
No Light: IECG is off and not producing chlorine. It may be in an
off-period of the sanitizing cycle and will return on shortly. This
light will also be blank if the water temperature is below
52° F +/-3° F (11° C +/ 1.67° C). This cold water cutoff mode
extends the blade life.
Flow: This light indicates the status of water flowing through the IECG.
Red: Insufficient water flow through the IECG, no chlorine is being produced.
Green: Sufficient water flow to produce chlorine.
IntelliChlor Control Panel
IntelliChlor Electronic Chlorine Generator Installation and User's Guide
Section 1
Salt Level
- high salt
FLASHING
Good
- good salt
G REEN
IDEAL SALT 3400 ppm
- add salt
- low salt
Low
RED
syste m off
Status
C old Water
-System Off
G REEN
- good
C ell
FLASHING
- inspect cell
ACID CLEAN EVERY 3 MONTHS
G REEN
- good flow
F low
- no flow
RED
(Syste m off )
Sanitizer Output
Min
40%
20%
60%
80%
100%
More
Les s
Pre ss both buttons simultaneou sly
for 24 hour 100% output
www.intellichlor.ne t
SWIMMING POOL AND
30ZR
SPA CHLORINATOR
NSF/ANSI Standard 50
7
Ma x
NS F
R
Certified to

Publicité

loading

Ce manuel est également adapté pour:

Intellichlor ic20Intellichlor ic40