1) Manufacturer name and address
2) Unit name and length
3) Unit code
4) Unit serial number
5) Supply voltage
6) Power supply frequency
7) Current absorbed in normal operation
8) Power absorbed during operation in refrigeration phase (fans + hot cables + lighting)
9) Power absorbed during operation in defrosting phase (Hot cables + evaporation fans + lighting +
defrost resistance if present)
10) Lighting power (where installed)
11) Usable display space
12) Type of refrigerant fluid used by the unit
13) Mass of refrigerating gas loaded in each individual unit
14) Environmental climate class and reference temperature
15) Anti-humidity protection class
16) Unit production work order number
17) Order number for unit production
18) Unit production year
In the case of a request for technical assistance, it is enough to communicate the following for identifi-
cation of the unit:
product name (Fig. 2 - 2); serial number (Fig. 2 - 4); work order number (Fig. 2 - 16).
5. TransportationFig. 3)
The cabinets are supplied on a wooden support fixed to the base for movement with forklift trucks.
Always position the forks at the point specified on the wooden support to avoid the risk of over-
turning. Use a manual or electrical forklift truck that is suitable to moving the cabinet in question. It
must have a nominal capacity of at least 1000 kg.
6. Receipt and initial cleaning
Upon receipt of the unit:
- Make sure that the packaging is intact and does not show any obvious damage;
- Carefully unpack the unit so as to not cause any damage;
- Check all parts of the unit, making sure that all components are intact;
- If any damage is found, immediately contact your supplier;
- Carry out an initial cleaning using neutral products and drying the unit with a soft cloth. Do not use
abrasive substances or metallic sponges.
- DO NOT use alcohol to clean the parts in Plexiglas.
For proper disposal of the packaging, please remember that it consists of:
Wood - Polystyrene - Polythene - PVC - Cardboard.
Pursuant to EEC Directive 94/62, the appropriateness of the above materials is here declared.
7. Installation and environmental conditions (Fig. 3)
For installation, please proceed as follows:
- Do not place the unit:
- in areas where explosive gaseous substances are present;
- outside and exposed to atmospheric agents;
- near heat sources (direct sunlight, heating systems, incandescent light bulbs);
- near air streams (near doors, windows, air conditioning units, etc.) that exceed the speed of 0.2m/
sec.
- Remove the wooden supports on the bottom (used for transportation) and attach the adjustable feet
(Rif. 2) positioning them so that the unit is horizontal, using a level (Rif. 1) to check the alignment.
Make sure that all the feet are touching the ground.
- If the unit is moved, repeat the leveling process.
- Before connecting the unit to the power supply, make sure that the rating plate information
corresponds to the characteristics of the electrical system to which it will be connected.
- For proper unit performance, the temperature and the relative humidity in the area must fall within the
05060090 00 12/02/2010
Lucerna 2
English
17